3 front panel configuration, Front panel configuration – Rice Lake SURVIVOR 420HE Hostile Environment - Installation Manual User Manual
Page 18
14
420HE Installation Manual
3.1.3
Front Panel Configuration
The
420HE
indicator can be configured using a series of menus accessed through the indicator front panel when the
indicator is in setup mode. Table 3-1 summarizes the functions of each of the main menus.
Table 3-1.
420HE Menu Summary
Menu
Menu Function
CONFIG
Configuration
Configure grads, zero tracking, zero range, motion band, overload, tare function, sample rate,
and digital filtering parameters.
FORMAT
Format
Set format of primary and secondary units, display rate.
CALIBR
Calibration
Calibrate indicator. See Section 4.0 on page 27 for calibration procedures.
SERIAL
Serial
Configure EDP and printer serial ports.
PROGRM
Program
Set power-up mode, regulatory mode, and consecutive number values.
PFORMT
Print Format
Set print format used for gross and net tickets. See Section 6.0 on page 35 for more
information.
SETPNT
Setpoint
Configure Setpoints and digital outputs.
DIG IN
Digital Input
Assign digital input functions.
ALGOUT
Analog Output
Configure analog output module. Used only if analog output option is installed.
VERS
Version
Display installed software version number.
Move UP/
Increrement
Value
ENTER
value
Move LEFT/
Previous
Move RIGHT/
Next
Move DOWN/
Decrement
Value
Figure 3-2. Front Panel Key Functions in Setup Mode
Four front panel keys are used as directional keys to navigate through the menus in setup mode (see Figure 3-2).
The
UNITS
( ) and
( ) keys scroll left and right (horizontally) on the same menu level;
ZERO
( ) and
GROSS/NET
( ) move up and down (vertically) to different menu levels. The
TARE
key ( ) serves as an Enter key
for selecting parameter values within the menus. A label above each of these keys identifies the direction provided
by the key when navigating through the setup menus.
1
st
Level
Parameter
Default value
Value
When moving thr ough values below the first menu level, press
to r etur n to the level
above. Press
or
to move to the next parameter on the level above
1
st
Level
Parameter
2
nd
Level
Parameter
2
nd
Level
Parameter
Value
Value