0 operation, 1 power, 2 zero – Rice Lake MSI-3460 Challenger 3 User Manual
Page 16: Operation, 1 power 2.2 zero

12 MSI-3460 Operator’s Manual
2.0
Operation
2.1 Power
To turn on the power.
1. Press
POWER
, the following will display in order:
• LED will light all segments at full brightness as a display test.
• Display brightness will change to the setting determined in the display menu.
• Software version number will display.
• The MSI-3460 is ready for use.
2.2 Zero
Sets the zero reading of the Scale. Use the
ZERO
key to take out small deviations in
zero when the scale is unloaded. See “TARE” for zeroing (Taring) package or pallet
weights.
1. Press
ZERO
Note
The weight reading must be stable within the motion window for the zero
function to work.
The scale digits display 0 (or 0.0 or 0.00, etc).
The backup memory in the MSI-3460 stores the zero reading, and can
restore it even if the power fails.
Rules for Use:
• Works in GROSS mode or NET mode. Zeroing while in net mode will zero
the gross weight causing the display to show the negative tare value.
• The scale must be stable within the motion window. The scale will not zero
if the motion detect annunciator is on. The scale will “remember” that it has
a zero request for two seconds. If motion clears in that time, the scale will
zero.
• The scale will accept a zero setting over the full range of the scale (NTEP
and other Legal for Trade models may have a limited zero range). Zero
settings above 4% of full scale will subtract from the overall capacity of the
scale. For example if you zero out 100 lb. on a 1000 lb. scale the overall
capacity of the scale will reduce to 900 lb. plus the allowed over-range
amount.