Normal mode commands, Unique commands, Setpoint tokens – Rice Lake Counterpart Configurable Counting Indicator - User Manual - Version 2.0 User Manual
Page 74

68
Counterpart User Manual
6.1.6
Normal Mode Commands
The normal mode print commands (see Table 6-10) transmit data to the serial port on demand in either setup or
normal mode.
6.1.7
Unique Commands
6.1.8
Setpoint Tokens
Command
Description
Values
CONSNUM#n
Set consecutive number
0–9 999 999
UID#n
Set unit ID
nnnnnnn
SD#n
Set date
MMDDYY, DDMMYY, YYMMDD, or YYDDMM. Enter six-digit
date using the year-month-day order specified for the DATEFMT
parameter, using only the last two digits of the year.
ST#n
Set time
hhmm (enter using 24-hour format)
SX#n
Start serial port streaming
OK or ??
An EX command sent while in menu mode does not take effect
until the indicator is returned to normal mode.
The EDP.Stream must be set to LFT or INDUST for this
command to work.
EX#n
Stop serial port streaming
XG#n
Transmit gross weight in displayed units
nnnnnn UU
where nnnnnn is the weight value, UU is the units.
NOTE: You can also send XGP, XGS, XGT, XTP, etc. to specify
primary, secondary or tertiary (P.S.T.).
XN#n
Transmit net weight in displayed units
XT#n
Transmit tare weight in displayed units
XA#n
Transmit accumulator value
RS
Reset system
Soft reset. Used to reset the indicator without resetting the
configuration to the factory defaults.
SK#n
Command to perform function assigned to softkey
Softkey digital I/O softkeys functions.
Table 6-10. Normal Mode Serial Commands
Command
Description
DUMPID.INDEX=n
To dump an ID by register
DUMPID.CODE=n
To dump an ID by code
KDISPMODE
Set or request the current display mode. KDISP=COUNT. Will switch to that mode. This only temporariliy
switches display. Default is set by dispmode parameter.
Other choices include:
COUNT
WEIGHT
UNIT WEIGHT
ETH.ECHO
Only applies when Vault is set to off.
Table 6-11. Unique Commands
Command
Description
Values
Setpoint captured value
9 characters maximum
Setpoint number
1 character maximum
Setpoint target value
9 characters maximum
Setpoint preact value
9 characters maximum
Setpoint weight mode
“gross” or “net”
Setpoint captured count value
9 characters maximum
Setpoint target count value
Setpoing preact count value
Table 6-12. Setpoint Token Commands