CB-2 Automated Concrete Batching System Installation/Operation Manual
Locations
You have the ability to Add, Copy, Change, Delete or Exit
Level 4 Sub-menu ADMIN MENU/APPLICATION PARAMETERS/DATABASES/LOCATIONS
Location ID
Store
Change
Enter in the bin/silo ID location. Press Store to keep that value or press
Change to change the value to a different one.
Name
Store
Change
Enter in the bin/silo name/description. Press Store to keep that value or press
Change to change the value to a different one.
Material
Store
Material
Enter in the material code. Press Store to keep that value or press Material to
change the material to a different one.
Delivery Mode
Change
Store
Enter in the delivery mode. Press Store to keep that value or press Change to
change the delivery mode to a different one.
1 - Single Speed
Secondary Mode
Off
On
Continuous Aeration
No Flow Aeration
Continuous Vibrator
No Flow Vibrator
Scale
Store
Scale
Enter in the scale. Press Store to keep that value or press Scale to change
the scale to a different one.
Fast Feed Gate
Change
Enter New Fast Feed Gate number.
Aerator
Change
Select to change aerator.
Feed Gate Limit Switch
Change
Select ot change the feed gate limit switch.
Fast Feed SP
Store
Change
Select to change the set point number that is used for fast filling.
Moisture Probe ID
Store
Change
Is a meter used to determine the moisture content of aggregates.
Press Store to keep the current parameter, or press Change to change the ID
and then press enter to save the new parameter.
Probe Mode
No Probe
Static Only
Static Flow
Flow Only
Moisture compensation mode.
Total Moisture
Store
Change
Enter in the total moisture. Press Store to keep that value or press Change to
change the total moisture value to a different one.
Scales
Select or Enter scale number. 1-Agg, 2-Cement
Level 4 Sub-menu ADMIN MENU/APPLICATION PARAMETERS/DATABASES/SCALES
Scale Number
Store
Change
Enter in the scale number. Press Store to keep that value or press Change to
change the scale number to a different one.
Name
Store
Change
Enter in the name/description of the scale. Press Store to keep that value or
press Change to change the name to a different one.
Capacity
Store
Change
Enter in the capacity of the scale. Press Store to keep that value or press
Change to change the capacity of the scale to a different one.
Zero Tolerance Band
Store
Change
Enter in the zero tolerance band. Press Store to keep that value or press
Change to change the value of the zero tolerance band to a different one.
Cleanout Time
Store
Change
Enter the cleanout amount time in seconds. Press Store to keep that value or
press Change to change the cleanout time to a different one.
Close Time
Store
Change
Enter the Close Time amount time in seconds. Press Store to keep that value
or press Change to change the close time to a different amount.
Discharge Delay
Store
Change
This is the amount of time the system waits before starting the first admixture
discharge. To change the amount of time (sec.), enter a new numeric value
and press the
enter
button to save the value.
Start Discharge % Full
Store
Change
Enter the discharge percent for the cement scale. Press Store to keep that
value or press Change to change the percent to a different amount.
ADMIN Menu
Parameter
Choices