Rice Lake CB-2 Concrete Batch Controller Version 1.0 User Manual
Page 27

Configuration of User Parameters
23
Application Parameters
ADMIN Menu
Parameter
Choices
Description
Level 2 Sub-menu
APPLICATION PARAMETERS
Level 3 Sub-menu
Batching Preferences
Level 4 Sub-menu ADMIN MENU/APPLICATION PARAMETERS/BATCHING PREFERENCES
Order Based Loading
No
Yes
Select Yes for order based loading to track order quantity, customer and job
ID.
Metric (S.I.) System
No
Yes
Select Yes to measure in metric units when kilograms are the primary unit of
measure.
State Regulatory Mode
Standard
MnDot
CAL TRAN
NYSDOT
Selects the desired state regulatory mode to weigh in.The CB-2 will function
slightly different to satisfy the selected state’s requirements.
Prompt for Truck ID
No
Yes
Selecting Yes for this option allows user to enter a character truck ID. At the
start of each batch the truck ID and driver name are then printed on the
batched ticket.
NET Mode Batching
No
Yes
Not used.
Split Batching Allowed
No
Yes
Selecting Yes for this option allows the user to split up a batch up to four
times the size of the plant.
Split Batch Even 1/4
No
Yes
Selecting Yes for this option allows the system to round the draft yards to the
nearest 1/4 yard to prevent odd draft sizes.
‘Discharge’ Keypress Required
Never
First Batch
Always
Select one of the options when a “discharge” keypress is required.
Aggregate Conveyor Control
Manual
Auto
Can select between Manual and Auto of the aggregate discharge conveyor. If
Manual is selected, the CB-2 does not attempt to start the conveyor. If Auto is
selected the CB-2 turns the aggregate discharge conveyor on and off as
needed. Note: if Auto is selected, it is critical that an audible alarm and light be
wired to the system alarm output to warn that the conveyor will be started.
Maintain Conveyor Power
No
Yes
Select Yes to maintain power to the conveyor system when the conveyor
should be running.
Boot Control
Manual
Auto
You can determine if you want the discharge boot to run manually or on auto,
otherwise a start pulse is sent to start the conveyor and another stop pulse is
sent to stop the conveyor.
Pipe Line/Preweigh Next Batch
No
Yes
Select Yes to pipeline the next batch.
Weigh-up Dust Collecting
No
Yes
Select Yes to do dust collection during the weigh up cycle.
Scale Inspect Mode
No
Yes
Select Yes to access the batch inspect mode. The inspect mode is useful for
state inspections that want to verify under/over tolerances.
ESTOP is Fatal
No
Yes
EStop will automatically abort the batch if yes is selected.
Air Pressure Sensor
No
Yes
Select Yes if the air pressure sensor is preset and should be used as an
interlock.
Auto Correct Jog Weights
No
Yes
Select Yes to do an auto correction of jog weights.
Zero Tolerance Override
No
Yes
Select Yes to allow a zero tolerance error, at the start of a batch to be
bypassed.
Table 4-1. Application Parameters Sub-menu List