Rice Lake CB-2 Concrete Batch Controller Version 1.0 User Manual
Page 28

24
CB-2 Automated Concrete Batching System Installation/Operation Manual
Auto Advance Jog Tuning
No
Yes
Select Yes to auto advance the tune jog procedure to the next jog time.
Start Allowed in ‘Manual’ mode
No
Yes
Select Yes to allow a batch to start while in manual mode.
Jog and Correct Last Batch
No
Yes
Batcher Air After Weigh-up
No
Yes
Select Yes to have the weigh hopper aeration start just after the last cement is
weighed up.
Batching Limits
Level 4 Sub-menu ADMIN MENU/APPLICATION PARAMETERS/BATCHING LIMITS
Maximum Plant Capacity
Enter a numeric value using
the 920i keypad
Enter the numeric value for the plant capacity
Enter the smallest quantity that should ever be batched.
Total cubic yards/meters batched since the system was last cleared.
Minimum Plant Capacity
Total Yards (Daily)
Total Yards (Weekly)
Total Yards(Monthly)
Total Yards (Yearly)
Water System
Level 4 Sub-menu ADMIN MENU/APPLICATION PARAMETERS/WATER SYSTEM
Weighed Water
No
Yes
Select Yes for the weighed water option.
Water Reservoir
No
Yes
Select Yes to designate whether or not your operation should use a water
reservoir during batching. Weighed water always uses a reservoir.
Start Water with Weigh-up
No
Yes
Select Yes to start water metering with the weigh up. This is not valid with a
reservoir.
Water to Truck First
No
Yes
Select Yes to have water added at the beginning of the discharge cycle, and
the aggregates and cements will not start discharging until all water (not
including the washout/tailwater) has been added.
Show ‘Start Water’ Softkey
No
Yes
Select Yes to show the ‘Start Water’ softkey during the weigh up cycle. See
‘Start Water’ softkey.
Suspend Water During Cement
No
Yes
Percent Tailwater
Enter a number for the percentage of gallons that are to be delivered after the
aggregates and cements have been discharged.
Minimum Tailwater Amount
On small batches, the percent tail wash may not hold back enough water.
Enter the minimum amount of gallons/liters that should always be held back.
Truck Washout Amount
Enter the gallon amount of water to wash off the boot and truck orifice.
Water Adjust per Batch
No
Yes
Select Yes to adjust the water on a per batch basis. Select No if the value
entered on the load preview screen is per yard.
Admix System
Level 4 Sub-menu ADMIN MENU/APPLICATION PARAMETERS/ADMIX SYSTEM
Suspend Admixture Addition
No
Yes
Select Yes to suspend the admixture additions without removing the admix
from the mix designs.
Single Empty Signal
No
Yes
Select Yes if all admixture bottles have only one empty signal together. Wire
this single signal to admix #1 bottle empty signal (5-5 terminal)
Mixing System
Level 4 Sub-menu ADMIN MENU/APPLICATION PARAMETERS/MIXING SYSTEM
ADMIN Menu
Parameter
Choices
Description
Table 4-1. Application Parameters Sub-menu List