Rice Lake CB-2 Concrete Batch Controller Version 1.0 User Manual
Page 29

Configuration of User Parameters
25
Enable Mixer Controls
No
Yes
Select Yes if your system has a mixer and you want the CB-2 to control it.
Continuous Batching
No
Yes
Select Yes for continuous batching to occur. Continuous batching will repeat
the same mix and quantity until the ‘Last Batch’ softkey is pressed.
Global Mix Time
Enter the amount of time in seconds the mixer should run
Auto Discharge Mixer
No
Yes
Select Yes to have the CB-2 discharge the mixer.
Mixer Discharge Time
Seconds
Enter the amount of time in seconds that the CB-2 should discharge the
mixer to ensure it is emptied completely.
Ticket/Reports Setup
Level 4 Sub-menu ADMIN MENU/APPLICATION PARAMETERS/TICKETS & REPORTS SETUP
Print Ticket Number
No
Yes
Select Yes to print the ticket number of the batch ticket.
# Line Feeds
Enter the number of lines that should be fed to achieve the correct starting
position.
Header Text Lines
Header Line 1 Left
Header Line 1 Right
Header Line 2 Left
Header Line 2 Right
Header Line 3 Left
Header Line 3 Right
Header Line 4 Left
Header Line 4 Right
Header Line 5 Left
Header Line 5 Right
Header Line 6 Left
Header Line 6 Right
Allows the user a total of 6 header lines in which to place text at the top of the
batch ticket (maximum of 60 characters per line). To change, press the
Change softkey and enter the new header line.
Plant Number
Enter numeric plant number
Print Customer & Job Site
No
Yes
Select Yes to print the customer and job site on the ticket.
Print Instructions /Notes
No
Yes
Select Yes to print any instructions and notes on the ticket.
Print Driver Name
No
Yes
Select Yes to have the drivers name attached to the printed ticket
Print Price
No
Yes
Select Yes to print the price per ... on to the printed ticket
Print Slump
No
Yes
Select Yes to print the slump on the printed ticket.
Print Job ID/Bridge #
No
Yes
Select Yes to print the job ID on the printed ticket.
Body Text Lines
Body Line 1 Left
Body Line 1 Right
Body Line 2 Left - up to 6
Right
Allows the user a total of 6 body lines in which to place the text in the middle
of the batch ticket (maximum of 60 characters per line). To change, press the
Change softkey and enter the new body line.
Batch Weights on Ticket
None
Load Totals
Individual Batches
Select for individual batch/load totals on the printed ticket.
Print Water/Cement Ratio
No
Yes
Select Yes to print the ratio of water to cement on the printed ticket.
Print Time Loaded
No
Yes
Select Yes to print the time loaded on the printed ticket.
ADMIN Menu
Parameter
Choices
Description
Table 4-1. Application Parameters Sub-menu List