Functions Setup 21
Command Format
1. Composed of four characters (ASCII), including the terminators CR=0DH, LF=0AH.
2. Instruction for tare subtraction (zero adjustment)
3. Setup of output control
The output controls executed with commands [O0] - [O7] work the same as the output controls executed
through function setup on the main unit of the balance. The commands [08] and [09] are data request
commands issued to the balance.
Once any command from [O0] - [O9] is executed, the balance runs that function until another command is
entered. However, if the balance is switched off and on again, the output control is reset to the initial function.
3.4.5
Response Output
1. Response output format is composed of five characters, including the terminators (CR=0DH, LF=0AH).
2. Types of response outputs:
1
2
3
4
C1
C2
CR
LF
C1
C2
Code
Description
Value
Response
T
(SP)
54H
20H Instruction for tare subtraction
(zero adjustment)
None
A00: Normal end
E01: Tare subtraction cannot be executed due
to an error in the weight value
C1
C2
Code
Description
O
0
4FH
30H
Stop output.
O
1
4FH
31H
Output continuous at all times.
O
2
4FH
32H
Output continuous if stable (stop output if unstable).
O
3
4FH
33H
Outputs once by pressing
Memory
(irrespective of whether stable)
O
4
4FH
34H
Output continuous at all times.
O
5
4FH
35H
Output continuous at all times.
O
6
4FH
36H
Output continuous at all times.
O
7
4FH
37H
Output continuous at all times.
O
8
4FH
38H
Output continuous at all times.
O
9
4FH
39H
Output continuous at all times.
1
2
3
4
5
A1
A2
A3
CR
LF
A1
A2
A3
Code
Description
A
0
0
41H
30H
30H Normal end
E
0
1
45H
30H
31H Command error
(Abnormal command received; other errors)