3 advanced calibration, Advanced calibration – Rice Lake Combination System - Precision Loads PL9710 Indicator User Manual
Page 10

6
PL9710 Installation Manual
4. The last number of the weight display will be
flashing, telling you that number is ready to be
changed. To change the number’s value, press the
Up
or
Down
key. To select a different number,
press the
left arrow
or
right arrow
softkey.
5. When the number on the weight display matches
your trailer’s (channel 1) loaded weight, press the
Enter
softkey to store the weight in the indicator’s
memory.
The information display will show Store Ch-1 full
weight then return to Setup selection. And the
weight display will show Setup.
6. To enter the trailer’s loaded weight, press the
Up
or
Down
key until the information display shows
Calibrate Channel 2.
7. Press the
Full
softkey. The information display
will briefly show Load Channel 2 before
Entering Full weight. It will then show Enter
Ch-2 Full Weight.
8. The last number of the weight display will be
flashing, telling you that number is ready to be
changed. To change the number’s value, press the
Up
or
Down
key. To select a different number,
press the
left arrow
or
right arrow
softkey.
9. When the number on the weight display matches
your trailer’s (channel 2) loaded weight, press the
Enter
softkey to store the weight in the indicator’s
memory.
The information display will show Store Ch-2 full
weight then return to Setup selection.
At any time, you can exit the calibration process by
pressing the
Cancel
softkey.
T h e i n f o r m a t i o n d i s p l a y w i l l b r i e f l y s h o w
CANCEL-Setup.
3.3 Advanced Calibration
Another way to enter the loaded weight into the
indicator is with the advanced calibration feature. This
method allows the calibration of several trucks to be
centrally controlled. The driver does not have to enter
the setup mode of the indicator, even for calibration.
After setting in the tare weight, the driver need only
record two sets of numbers:
• The truck and trailer loaded weight shown by the
platform scale.
• The channel 1 and channel 2 weights recorded on
the
PL9710
while the truck is on the platform scale.
The following steps are used for the advanced
calibration, which can be done on an empty truck.
1. Press the
Menu
key for 5 seconds until the
information display shows Setup Menu.
After releasing the
Menu
key, the information
display will show Setup selection and the weight
display will show Setup.
2. Press the
Up
or
Down
key until the information
display shows Set Advanced calibration.
3. Select the channel to calibrate by pressing the
CH-1
softkey or the
CH-2
softkey.
For this example, we will assume you selected
CH-1.
4. Enter the number that was earlier recorded as the
number shown on the indicator’s weight display
for channel 1 while sitting on the platform scale.
Change the numbers in the same manner as then
setting the original loaded-weight calibration. See
“Entering the Loaded Weight” on page 5. Press
the
Enter
softkey when completed.
5. The information display will show
Enter Ch. 1
Legal weight
.
6. Enter the number that was earlier recorded as the
legal truck weight from the platform scale.
Change the numbers in the same manner as in
Step 4, above.
7. Press the
Enter
softkey when completed.
The information display will show Advanced
calibration Ch. 1 and then show Setup selection.
8. Press the
Cancel
softkey to return to normal
operation.
Channel 2 is calibrated in a similar manner.
Note