6 batching control commands, 7 database commands, Batching control commands – Rice Lake 920i Installation Manual V1.05 User Manual
Page 83: Database commands

Serial Commands
79
9.1.6
Batching Control Commands
The commands listed below provide batching control
through the serial port.
BATSTART
If the BATRUN digital input is active (low) or
not assigned, the BATSTART command can be
used to start the batch program.
BATRESET
Stops the program and resets the batch program
to the Þrst batch step. Run the BATRESET
command after making changes to the batch
conÞguration.
BATPAUSE
Stops the batch program at the current step. All
digital outputs set on by the current step are set
off. The BATSTRT DIGIN, BATSTART serial
command,
Batch Start
softkey, or the StartBatch
function in an
iRite
program can be used to
restart the batch program at the current step.
9.1.7
Database Commands
The commands listed in Table 9-12 can be used to
create and maintain databases in the
920i
. Except for
t h e
D B . D E L A L L
c o m m a n d , a l l o f t h e d a t a b a s e
commands require an extension to identify the number
of the database within the memory card and the slot
number of the memory card.
RS
Reset system
Soft reset. Used to reset the indicator without resetting the
configuration to the factory defaults.
XA#n
Transmit accumulator value in displayed units
nnnnnn UU
XAP#n
Transmit accumulator value in primary units
XAS#n
Transmit accumulator value in secondary units
XAT#n
Transmit accumulator value in tertiary units
XG#n
Transmit gross weight in displayed units
nnnnnn UU
XGP#n
Transmit gross weight in primary units
XGS#n
Transmit gross weight in secondary units
XGT#n
Transmit gross weight in tertiary units
XN#n
Transmit net weight in displayed units
nnnnnn UU
XNP#n
Transmit net weight in primary units
XNS#n
Transmit net weight in secondary units
XNT#n
Transmit net weight in tertiary units
XT#n
Transmit tare weight in displayed units
nnnnnn UU
XTP#n
Transmit tare weight in primary units
XTS#n
Transmit tare weight in secondary units
XTT#n
Transmit tare weight in tertiary units
XE
Query system error conditions
nnnnn
See Section 10.1.4 on page 89 for detailed information
about the XE command response format.
Command
Description
Values
Table 9-11. Normal Mode Serial Commands
Command
Description
DB.ALIAS.n#x
Get or set database name
DB.CLEAR.n#x
Clear database contents
DB.DATA.n#x
Get or set database contents
DB.SCHEMA.n#x
Get or set database structure
DB.DELALL
Delete all databases and database
contents
n represents the database number within the memory card;
x is the slot number of the memory card.
Each command must be terminated with a carriage return
character (
Table 9-12. Database Commands