Rice Lake 920i Installation Manual V1.05 User Manual
Page 78

74
920i
Installation Manual
SC.SMPRAT#n
Sample rate
30, 60, 120, 240, 480, 960
SC.PWRUPMD#n
Power up mode
GO, DELAY
SC.TAREFN#n
Tare function
BOTH, NOTARE, PBTARE, KEYED
SC.PRI.DECPNT#n
Primary units decimal position
8.888888, 88.88888, 888.8888, 8888.888, 88888.88, 888888.8,
8888888, 8888880, 8888800
SC.PRI.DSPDIV#n
Primary units display divisions
1D, 2D, 5D
SC.PRI.UNITS#n
Primary units
LB, KG, G, OZ, TN, T, GN, TROYOZ, TROYLB, LT, CUSTOM, NONE
SC.SEC.DECPNT#n
Secondary units decimal
position
8.888888, 88.88888, 888.8888, 8888.888, 88888.88, 888888.8,
8888888, 8888880, 8888800
SC.SEC.DSPDIV#n
Secondary units display divisions 1D, 2D, 5D
SC.SEC.UNITS#n
Secondary units
LB, KG, G, OZ, TN, T, GN, TROYOZ, TROYLB, LT, CUSTOM, NONE
SC.SEC.MULT#n
Secondary units multiplier
0.00000–9999999
SC.TER.DECPNT#n
Tertiary units decimal position
8.888888, 88.88888, 888.8888, 8888.888, 88888.88, 888888.8,
8888888, 8888880, 8888800
SC.TER.DSPDIV#n
Tertiary units display divisions
1D, 2D, 5D
SC.TER.UNITS#n
Tertiary units
LB, KG, G, OZ, TN, T, GN, TROYOZ, TROYLB, LT, CUSTOM, NONE
SC.TER.MULT#n
Tertiary units multiplier
0.000001–9999999
SC.ROC.DECPNT#n
Tertiary units decimal position
8.888888, 88.88888, 888.8888, 8888.888, 88888.88, 888888.8,
8888888, 8888880, 8888800
SC.ROC.DSPDIV#n
Rate-of-change units display
divisions
1D, 2D, 5D
SC.ROC.MULT#n
Rate-of-change units multiplier
0.000001–9999999
SC.ROC.UNITS#n
Rate-of-change units
SEC, MIN, HOUR
SC.ROC.INTERVL#n
Rate-of-change interval
1–65535
SC.ROC.REFRESH#n
Rate-of-change refresh interval
1–65535
SC.ACCUM#n
Accumulator enable
ON, OFF
SC.VISIBLE#n
Scale visibility
ON, OFF
SC.WZERO#n
Zero calibration
—
SC.WVAL#n
Test weight value
test_weight_value
SC.WSPAN#n
Span calibration
—
SC.WLIN.F1#n–
SC.WLIN.F5#n
Actual raw count value for
linearization points 1–5
0–16777215
SC.WLIN.V1#n–
SC.WLIN.V5#n
Test weight value for linearization
points 1–5
0.000001–9999999
SC.WLIN.C1#n–
SC.WLIN.C5#n
Calibrate linearization points 1–5
—
SC.LC.CD#n
Set deadload coefficient
—
SC.LC.CW#n
Set span coefficient
—
REZERO#n
Rezero —
For commands ending with “#n”, n is the scale number.
Command
Description
Values
Table 9-3. SCALES Serial Commands (Continued)