Horizontal-weep-holes – Oldcastle BuildingEnvelope Reliance StormMax High Performance User Manual
Page 27
![background image](/manuals/638808/27/background.png)
February 2014
25-Horizontal-Weep-Holes
1-866-Oldcastle (653-2278) www.oldcastlebe.com
HW-163 cut length =
D.L.O. minus 1/4"
5/16" dia. weep holes locate at 1/4 points
WW-1328 face cap
weep horizontal cap
at mid-lite.
See detail below
7/32"
Centerline
of D.L.O
5/16" dia. weep hole
Horizontal Face Cap Fabrication
GP-165 gasket.
See notes below for
installation
Glazing Notes:
1. GP-165 Gasket used on exterior of system.
2. Remove gaskets from reels and allow to relax overnight before installing.
3. Cut gaskets to allow minimum 1/4" per foot for any relaxation of gasket
ends of each horizontal pressure plate as required. locate at 1 1/2" maximum from the ends.
FS-325 screw
(FS-322 at 1/4" system)
FIGURE 3.5b
Glazing Instructions
GLAZING INSTRUCTIONS
RELIANCE STORMMAX HIGH PERFORMANCE INSTALLATION MANUAL
Seal ends of
pressure plate to
vertical cap