Pressure-plate-fab – Oldcastle BuildingEnvelope Reliance StormMax High Performance User Manual
Page 12
![background image](/manuals/638808/12/background.png)
February 2014
10-Pressure-Plate-Fab
1-866-Oldcastle (653-2278) www.oldcastlebe.com
1.6 a. Cut HW-163 Pressure Plate to D.L.O. minus 1/4" for horizontal members.
b. Drill (2) 5/16" weep holes at 1/4 points into corner of raised section at a 45 degree angle of
HW-163 Pressure Plate. See Figure 1.9a
c. Cut HW-163 Pressure Plates vertical members to Frame Height minus 1/4".
d. Cut GP-165 Gasket to D.L.O. plus 3/16" for relaxation on horizontal members. Vertical members
are cut to frame height plus 1/4". Crowd gasket into riglet. See FIGURE 1.6b
PRESSURE PLATE FABRICATION
HW-163 Pressure Plate
Locate weep holes at quarter points
Drill (2) 5/16" weep holes
at a 45 degree angle.
Locate at 1/4 points
of each end of member.
D.L.O
MINU
S 1/4
"
FIGURE 1.6a
Horizontal Pressure
Plate Fabrication
HW-163 Pressure Plate
RELIANCE STORMMAX HIGH PERFORMANCE INSTALLATION MANUAL