06 product configs – Oldcastle BuildingEnvelope Reliance-TC User Manual
Page 6
SYSTEM CONFIGURATIONS
R E L I A N C E - T C C U R T A I N W A L L I N S T A L L A T I O N M A N U A L
TM
Reliance-TC is available in multiple configurations to provide a range of thermal
performance capabilities and installation options. See details below for system details.
Reliance-TC Type I
(WW-520 vertical, std Reliance
horizontals)
Reliance-TC Type II
(AW-520 vertical and composite
horizontals)
Reliance-TC Type II w/ FRP pressure plate
(AW-520 vertical, composite horizontals
& AW-162 FRP pressure plate)
Reliance-TC Type I w/ FRP horiz. pressure plates
(WW-538 vertical, std Reliance horizontals
with AW-162 FRP Pressure Plate)
Details above show extrusion numbers for the 7-1/4" (7-1/2") systems. Alternate depths are also available. See
our website: www.oldcasltebe.com/products/curtain-wall/pressure-wall/reliance-tc for additional information.
*Reference Oldcastle BuildingEnvelope FRP Pressure Plate Installation Manual for information regarding
installation and sealant of FRP Pressure Plates.
Type I features a thermal composite vertical with integrated
exterior face cover and the standard Reliance horizontals.
Type II features thermal composite horizontals and verticals with a
27mm thermal strut and pressure plates on all verticals and horizontals.
Installation Note:
1) Type II composite horizontals may be used in the Type I system to
improve thermal performance.
2) AW-162 FRP pressure plates* may be used with either system for
improved thermal performance. Face cap depth for FRP pressure plates
is 3/4" minimum.
MAY 2013
6
Phone: 1-866-OLDCASTLE (653-2278)
Web Address: www.oldcastlebe.com
®