20 frame install, Step 3, Step 2 – Oldcastle BuildingEnvelope Reliance-TC User Manual
Page 20
R E L I A N C E - T C C U R T A I N W A L L I N S T A L L A T I O N M A N U A L
TM
STEP 3
1" min.
FIGURE 15 cont.
Type I Zone Plug Installation
STEP 2
Apply additional sealant to
zone plug at mullion and
horizontal. Marry sealant
with sealant applied
into mullion races.
Tool sealant into pockets
of zone plug at mullion
and horizontal.
Force sealant into gasket
races at interior and
exterior of glazing pocket
Apply sealant to end of horizontal
prior to installing zone plug
FRAME INSTALLATION
MAY 2013
20
Phone: 1-866-OLDCASTLE (653-2278)
Web Address: www.oldcastlebe.com