beautypg.com

15 frame install, Frame installation – Oldcastle BuildingEnvelope Reliance-TC User Manual

Page 15

background image

R E L I A N C E - T C C U R T A I N W A L L I N S T A L L A T I O N M A N U A L

TM

FRAME INSTALLATION

FIGURE 10

Vertical Splicing @

Type II Verticals

4"

1 1/2"

3"

3/4"

1"

min.

STEP 1

STEP 2

MAY 2013

15

Phone: 1-866-OLDCASTLE (653-2278)

Web Address: www.oldcastlebe.com

FS-8

#14 x 1" HHSTS

(2) per side

Apply bond breaker

tape along face of splice

Insert backer rod

into tongue of upper

& lower mullions

Attach splice with FS-8 (#14 x 1" HHSTS),

(2) per side (fasteners required for
deadload splice only. Omit for
expansion connection).

Seal joint between

mulls. Seal must run

across face, tongue

& min 1" down sides

of mullion.

Install splice

sleeve to each
side of mullion

1/2" joint

based on 1/4"

expansion.