10 frame fab – Oldcastle BuildingEnvelope Reliance-TC User Manual
Page 10

FRAME FABRICATION
R E L I A N C E - T C C U R T A I N W A L L I N S T A L L A T I O N M A N U A L
TM
1.3 Fabricate vertical mullions for horizontal members using the DJ-100 drill jig. Drill holes for shear block using
holes marked "A" and "B". SEE FIGURE 3. When working off horizontal centerlines, use the scored lines to align the
jig with the centerline.
FIGURE 3
Vertical Fabrication
Top of
horiozontal
FS-9 (typ)
WW-181-01
WW-104-01 anchor optional
for head or sill Maximum load
375 lbs per anchor.
(750 lbs. end reaction)
1 1/4"
#11 (.191Ø) holes for
#14 fasteners
2 1/4"
3/4"
A
A
B
C
D
C
C
D
C
2 1/4"
3/4"
1 1/4"
Top of
horizontal
1 1/4"
typ.
AW-181-01
WW-102-01 Tee
anchor @ mullion
WW-103-01 F
anchor @ jamb
Seal mull cap
Apply sealant
to mullion prior
to installing
mull cap
Type I
Vertical Layout
Type II
Vertical Layout
AW-181-01
(Optional)
MAY 2013
10
Phone: 1-866-OLDCASTLE (653-2278)
Web Address: www.oldcastlebe.com