3
7/
16"
3 7/16"
3/4
"
FS-325
#12-24 X 1 1/2"
DrillFlex
AD-450
Subframe
AD-403
Door stop
WW-122
WW-122
FIGURE 42
Attaching Thermal
Door Subframe
THERMAL ENTRANCE FRAMES
C.3 THERMAL SUBFRAME INSTALLATION:
C.3.1 Attach AD-204 threhsold clip to bottom of each subframe jamb with two (2) FS-22 #10 x 1/2" Flat
Head Screws
C.3.2 Install WW-122 filler into verticals and horizontal, attach w/ FS-325 @ 18" o.c. Bed fillers in sealant
and cap seal fasteners at all fillers.
C.3.3 Bed subframes in sealant and anchor to curtain wall framing members with FS-325#12-24 x 1 1/2"
Drillflex at 18" on center. Seal joint between jamb and header subframes. Seal also tops of jamb subframe.
SEE FIGURE 42
.
C.3.4 Bed threshold in sealant, attaching TH-44 clips with FS-42 #12 x 1/2" Phillips Flat Head screws. Marry
threshold seal with subframe and main system seal.
C.3.5 Install door stops onto subframe with SC-1 clips and FS-15 rivets @ 18" O.C. Locate clips around the
subframe anchor screws. Vertical stops run through.
C.3.6 Install door per DOOR & FRAME INSTALLATION & GLAZING MANUAL
R E L I A N C E - T C C U R T A I N W A L L I N S T A L L A T I O N M A N U A L
TM
MAY 2013
40
Phone: 1-866-OLDCASTLE (653-2278)
Web Address: www.oldcastlebe.com