21 frame install, Figure 16 type ii zone plug installation – Oldcastle BuildingEnvelope Reliance-TC User Manual
Page 21
FRAME INSTALLATION
R E L I A N C E - T C C U R T A I N W A L L I N S T A L L A T I O N M A N U A L
TM
FIGURE 16
Type II Zone Plug Installation
STEP 1
STEP 2
STEP 3
ZONE PLUG AT HEAD
ZONE PLUG AT JAMB
ZONE PLUG AT SILL
WW-370 zone plug
Tool sealant along top
of zone plug to form
a water tight seal.
Seal along tongue of
horizontal & across face and
tongue of mullion before
installing zone plugs.
Seal between gaskets
prior to installing glass.
Force sealant into
pockets to seal
ends of struts at
head, sill and
horizontals.
Force sealant
into gasket race
Seal between
sill, vertical &
mullion cap
Seal jamb & sill
zone plugs same
as shown at left
Bottom side of
zone plug shown.
Seal top side sim.
Seal between head,
vertical mullion and
mullion cap
Apply generous bead
of sealant to face of
zone plugs just prior
to installing vertical
pressure plate.
MAY 2013
21
Phone: 1-866-OLDCASTLE (653-2278)
Web Address: www.oldcastlebe.com