Chapter 2: installation – Kontron X9SCL+-F User Manual
Page 49

Chapter 2: Installation
2-23
NIC1/NIC2 (LAN1/LAN2)
The NIC (Network Interface Controller) 
LED connection for LAN port 1 is located 
on pins 11 and 12 of JF1, and the LED 
connection for LAN Port 2 is on Pins 9 
and 10. NIC1 LED and NIC2 LED are 
2-pin NIC LED headers. Attach NIC LED 
cables to NIC1 and NIC2 LED indicators 
to display network activities. Refer to the 
table on the right for pin definitions.
LAN1/LAN2 LED
Pin Definitions (JF1)
Pin# Definition
9/11
Vcc
10/12
LAN Active
A. NIC1 LED
B. NIC2 LED
C. OH/Fan Fail/UID LED
Overheat (OH)/Fan Fail/Front UID LED
Connect an LED cable to the Front UID and 
OH/Fan Fail connections on pins 7 and 8 
of JF1 to display UID (Unit ID) signals or 
to provide advanced warnings for chassis 
overheat/fan failure. Refer to the table on 
the right for pin defi nitions.
OH/Fan Fail LED
Pin Definitions (JF1)
Pin# Definition
7
Vcc/Blue UID LED
8
OH/Fan Fail LED
OH/Fan Fail Indicator
Status
State Definition
Off
Normal
On
Overheat
Flash-
ing
Fan Fail
C
A
B
Power Button
OH/Fan Fail LED
1
NIC1 LED
Reset Button
2
HDD LED
Power LED
Reset
PWR
LED_Anode+
LED_Anode+
LED_Anode+
UID LED
Ground
Ground
Power Fail LED
NIC2 LED
LED_Anode+
LED_Anode+
