beautypg.com

4 electrical specifications, 1 supply voltage, Atc power – Kontron COMe-cOHXX User Manual

Page 18: Single power supply, 2 supply current (windows xp sp3), Electrical specifications, Supply voltage, Supply current (windows xp sp3)

background image

Kontron COMe-cOH2/COMe-cOH6 User’s Guide

www.kontron.com

13

All dimensions are shown in millimeters. The COM Express® specification says

that these holes should be ± 0.25mm [±0.010"], unless otherwise noted. The

tolerances for placement of the COM Express connector with respect to the peg

holes (dimensions [16.50, 6.00]) should be ± 0.10mm [±0.004"]. The mounting

holes shown in the drawing use 6mm diameter pads and 2.7mm plated holes for

use with 2.5mm hardware. The pads are tied to the PCB ground plane. Black

circles represent the mounting holes required by the PICMG COM Express®

standard.

3.4

Electrical Specifications

3.4.1

Supply Voltage

ATC Power

»

4.75V to +18V main power is on the COM Express VCC_12V pins and 4.75V to

5.25V standby power is on the VCC_5V_SBY. RTC power is provided on the

VCC_RTC pins. VCC_12V may or may not collapse in suspend states S3, S4, and

S5.

Single Power Supply

»

4.75V to +18V main power is on the COM Express VCC_12V pins and standby

power if needed is also provided on the VCC-12V pins. The VCC_5V_SBY pins

may be floating or may be tied to a 5V source on the carrier board. RTC

power is provided on the VCC_RTC pins.

Power Supply Risetime

To be supplied in a future release of this manual.

3.4.2

Supply Current (Windows XP SP3)

The testing performed to capture the supply current data used tested modules

mounted on a Kontron evaluation board with a mouse and keyboard connected.

The power consumption tests were executed in Windows XP (with SP3) using a

tool to stress the CPU at 100 % load. The power measurement values were

captured after 15 minutes of full load or a stable CPU core temperature of

90°C. To ensure a stable die temperature, a corresponding heat sink was used

to hold the temperature under the critical trip point. The modules were

tested using the maximum CPU frequency. For more detailed information, refer

to the “Power Consumption” diagrams on the EMD Customer section of the

Kontron website.

Table 1: AMD G-Series APU