beautypg.com

Kontron AT8940 User Manual

Page 20

background image

Product Description

5

AT8910/AT8940

www.kontron.com

System Manager

Support for basic and micro COM Express ETX Modules with Type 1 connector, according

COMExpress 0 R1.0

Management connection to System Manager via RS232 front RJ45.

Basic and Micro ETX use SuperIO LPC to UART Bridge

UART switched through FPGA

Management connection to System Manager using front 10/100/1000Base-T RJ45 management

port.

Front panel USB port

Support of ETX modules up to 30W

Additional Ethernet Connection to Base IF and redundant HUB via Dual Ethernet Controller Intel

82580DB

1000Base-BX to Base Switch

1000Base-BX to Update Channel

Support for JEDEC SerialATA MO-297 SSD, Port 0 and Port 2

Support for RTM SATA applications, Port 1 and Port 3

Support of up to 2 eUSB Flash Modules

Power Requirements

120 W* -38V @ -72V with 12GB of memory, no RTM. Maximum of 225W
* The power consumption will vary depending on your product configuration (RTM & extra memory)

Environmental

Temperature*

Operating: 0-55°C/32-131°F with 30CFM airflow
Storage and Transit: -40 to +70°C/-40 to 158°F

Environmental

Humidity*

Operating: 15% to 90% @55°C/131°F non-condensing
Storage and Transit: 5% to 95% @ 40°C/104°F non-condensing

Environmental Altitude*

Operating: 4,000 m / 13,123 ft
Storage and Transit: 15,000 m / 49,212 ft

Environmental Shock*

Operating: 3G each axis
Storage and Transit: 18G each axis

Environmental

Vibration*

Operating: 5-200Hz. 0.2G, each axis
Storage and Transit: 5Hz to 20Hz @ 1 m2/s3 (0.01g2 /Hz) (flat)
20Hz to 200Hz @ -3dB/oct (slope down)

Reliability

Whole board protected by active breaker

USB voltage protected by an active breakers

Safety / EMC

Meet or exceed:

Safety: UL 60950-1; CSA C22.2 No 60950-1-03; EN 60950-1:2001; IEC60950-1

EMI/EMC: FCC 47 CFR Part 15, Class B; CE Mark to EN55022/EN55024/EN300386

Warranty

Two years limited warranty

Features

Description

This manual is related to the following products: