5 applied standards, 1 ce compliance, 2 mechanical compliance – Kontron VSBC-32 User Manual
Page 30: 3 environmental tests, Applied standards - 14, Ce compliance - 14, Mechanical compliance - 14, Environmental tests - 14, Vsbc-32 introduction
VSBC-32
Introduction
ID 21168, Rev. 04
Page 1 - 14
©
PEP Modular Computers GmbH
1.5 Applied Standards
1.5.1
CE Compliance
The
PEP Modular Computers’ VMEbus and (e)CXC systems comply with the require-
ments of the following CE-relevant standards:
•
Emission
EN50081-1
•
Immission
EN50082-2
•
Electrical Safety
EN60950
1.5.2
Mechanical Compliance
•
Mechanical Dimensions
IEEE 1101.10
1.5.3
Environmental Tests
•
Vibration
IEC68-2-6
•
Permanent Shock
IEC68-2-29
•
Single Shock
IEC68-2-27
Power Consumption
•
VSBC-32:
typ. 3.0W
•
VSBC-32E:
typ. 3.5W
Temperature Ranges
Operation:
0° C to 70° C
(standard)
-40° C to +85° C
(extended)
Storage:
-55° C to +125° C
Humidity
0..95%, non-condensing
Dimensions
4HP/3U Eurocard (100mm x 160mm)
Weight
Mainboard:
130g
Serial interface piggyback:
20..30g
Memory piggyback:
30g
Table 1-2: VSBC-32(E) Technical Specification (Sheet 3 of 3)
VSBC-32(E)
Specification