beautypg.com

Anchoring & sealing, B) temporary glazing usin, A) glass size & glass setting – EFCO 960 Series User Manual

Page 47: Fig. # 40, Fig. # 39, Screw spline / shear block installation

background image

to the exterior,
do not seal
this front
seam.

moisture migration

To allow for

FIG. # 40

Apply sealant to the upturned
leg before setting the unit in place.

FIG. # 39

6" from the ends

OF SEALANT.

KEEP THIS GLAZING

FROM ANY TYPE

LEG FACE FREE

and 24" on center.

Shim and anchor

HEAD AND JAMBS AT

AND THE EXTERIOR.

SEAL THE PERIMETER

BOTH THE INTERIOR

the perimeter

PAGE 45

JDA 6/2002

LEG FACE FREE
FROM ANY TYPE

KEEP THIS GLAZING

OF SEALANT.

silicone type sealant (D.C.795).

Seal horizontal cavities that
are accessible with a

SEAL ALL JAMB CAVITIES

WITH A SILICONE

TYPE SEALANT.

SEALANT

SECTION VIII A -

SCREW SPLINE / SHEAR BLOCK

INSTALLATION

FRAME ANCHORING

Before the fastener is inserted, force

sealant into the hole for the sill
perimeter fastener to ensure that the

hole through the sill flashing is sealed.
Cover the heads of all fasteners
with sealant as shown.

960 WALL

AND SEALING