What is included in the box, Recommended tools, Wiring for – Detex DS-1481 User Manual
Page 2: Fail-secure mode, Fail-safe mode
WHAT IS INCLUDED IN THE BOX:
INCLUDED IN THE BOX ARE:
1 - (1) Surface Mounted Strike
2 - (2) 1/4-20 x 1 inch UH Cap Socket Mounting Screws
3 - (4) Anchor System Pins
4 - (1) Quick Connect Socket and Wire Assembly
5 - (2) Sealed Crimp Connectors
6 - (1) In Polybag - Fail Safe Spring (RED colored) for Solenoid
7 - (1) 1/8 inch Thick Spacer Plate/Frame Mounting Template
RECOMMENDED PREINSTALLATION CHECK
FOR SURFACE MOUNT STRIKE
1. Determine that door is properly adjusted; Door must operate
properly in order for system to provide best results.
2. Door must swing properly, without interfering with jamb or sill
3. The door should be equipped with a door closer and the door
closer “latch mode” must hold door in a completely closed
position in order to avoid the lock latch from applying pressure
against the releasing latch portion of the electric strike.
4. Electrical wire connections must be completed and ready to
be terminated inside the frame.
5. Confirm that the power line in the frame is the correct voltage
and that the switch works properly.
5. Confirm proper clearance exists between the end of the lock
latch and jamb.
7. The electric door strike must be aligned properly with lock
latch when it is installed on the doorjamb.
8. For best installation results, the door frame must be
reasonably flat and straight.
2
RECOMMENDED TOOLS:
- 3/32 inch Allen Wrench
- 3/16 inch Allen Wrench
- 3/4 inch diameter Drill Bit
- #7 Drill Bit
- #30 Drill Bit
(for the optional Anchor Pins)
- 1/4-20 Tap
- Drill
- Marker
WIRING FOR
FAIL-SECURE MODE
TO 120V
AC LINE
SWITCH
NORMALLY
OPEN
USE 12V THRU 24V
AC OR DC
TRANSFORMER
OPTIONAL BUZZER
NOTE: MATCH THE VOLTAGE
OF THE TRANSFORMER
AND IF REQUIRED,
OBSERVE POLARITY
TO 120V
AC LINE
SWITCH
NORMALLY
CLOSED
USE 12V THRU 24V
AC OR DC
TRANSFORMER
TO 120V
AC LINE
SWITCH
SINGLE POLE
DOUBLE THROW
USE 12V THRU 24V
AC OR DC
TRANSFORMER
OPTIONAL BUZZER
NOTE: MATCH THE VOLTAGE
OF THE TRANSFORMER
AND IF REQUIRED,
OBSERVE POLARITY
WIRING FOR
FAIL-SAFE MODE
WIRING FOR
FAIL-SAFE MODE
WITH OPTIONAL BUZZER
FAIL-SAFE
CONFIGURED
STRIKE
FAIL-SAFE
CONFIGURED
STRIKE
FAIL-SECURE
CONFIGURED
STRIKE