WHAT IS INCLUDED IN THE BOX:

INCLUDED IN THE BOX ARE:
1 - (1) Surface Mounted Strike

2 - (2) 1/4-20 x 1 inch UH Cap Socket Mounting Screws

3 - (4) Anchor System Pins

4 - (1) Quick Connect Socket and Wire Assembly

5 - (2) Sealed Crimp Connectors

6 - (1) In Polybag - Fail Safe Spring (RED colored) for Solenoid

7 - (1) 1/8 inch Thick Spacer Plate/Frame Mounting Template

RECOMMENDED PREINSTALLATION CHECK

FOR SURFACE MOUNT STRIKE

1. Determine that door is properly adjusted; Door must operate

properly in order for system to provide best results.

2. Door must swing properly, without interfering with jamb or sill

3. The door should be equipped with a door closer and the door

closer “latch mode” must hold door in a completely closed

position in order to avoid the lock latch from applying pressure

against the releasing latch portion of the electric strike.

4. Electrical wire connections must be completed and ready to

be terminated inside the frame.

5. Confirm that the power line in the frame is the correct voltage

and that the switch works properly.

5. Confirm proper clearance exists between the end of the lock

latch and jamb.

7. The electric door strike must be aligned properly with lock

latch when it is installed on the doorjamb.

8. For best installation results, the door frame must be

reasonably flat and straight.

2

RECOMMENDED TOOLS:

- 3/32 inch Allen Wrench

- 3/16 inch Allen Wrench

- 3/4 inch diameter Drill Bit

- #7 Drill Bit

- #30 Drill Bit

(for the optional Anchor Pins)

- 1/4-20 Tap

- Drill

- Marker

WIRING FOR

FAIL-SECURE MODE

TO 120V

AC LINE

SWITCH

NORMALLY

OPEN

USE 12V THRU 24V

AC OR DC

TRANSFORMER

OPTIONAL BUZZER

NOTE: MATCH THE VOLTAGE

OF THE TRANSFORMER

AND IF REQUIRED,

OBSERVE POLARITY

TO 120V

AC LINE

SWITCH

NORMALLY

CLOSED

USE 12V THRU 24V

AC OR DC

TRANSFORMER

TO 120V

AC LINE

SWITCH

SINGLE POLE

DOUBLE THROW

USE 12V THRU 24V

AC OR DC

TRANSFORMER

OPTIONAL BUZZER

NOTE: MATCH THE VOLTAGE

OF THE TRANSFORMER

AND IF REQUIRED,

OBSERVE POLARITY

WIRING FOR

FAIL-SAFE MODE

WIRING FOR

FAIL-SAFE MODE

WITH OPTIONAL BUZZER

FAIL-SAFE

CONFIGURED

STRIKE

FAIL-SAFE

CONFIGURED

STRIKE

FAIL-SECURE

CONFIGURED

STRIKE