beautypg.com

Salter Brecknell 304BP User Manual

Page 26

background image

26

APPENDIX C: ERROR MESSAGES

C.1 ERROR MESSAGES

If the scale encounters an error condition, it will display a message alerting the operator. A

description of each display follows:

C.1.1 OPERATOR ERRORS

Message

Explanation

“o o o o o o”

Indicates that the weighing capacity of the scale has been

exceeded.

Add

Indicates that there is not enough internal resolution to

calculate the unit weight of an item. This means that the

items you are counting are too light for the scale to

process at all.

Lo

Indicates that unit weight of the items you are sampling

is too light for the scale to process accurately.

O L

Indicates that value in the accumulator exceeds the

display capacity of the scale.

Err 10

Scale cannot read serial number. Scale must be returned for

service.

Err 11

Serial number mismatch. Re-enter setting code from product

ID tag.

Err 12

Invalid setting code. Re-enter proper setting code from

product ID tag.

Note:

Contact Service Department at Salter Brecknell for instructions on how to re-enter setting

code.