B.2.3 RECOGNIZED HOST COMMANDS
“P”
- This command is sent to the scale to print the indicated display. The scale will
not respond if the scale is in motion, positive overload or negative overload.
“Z”
- This command is sent to the scale to zero the scale. The scale will not respond
if the scale is in motion, positive overload or negative overload.
“M”
- This command is sent to the scale to add an entry to the accumulator (M+).
“R”
- This command is sent to the scale to recall the contents of the accumulator
(MR).
“C”
- This command is sent to the scale to clear the contents of the accumulator
(MC).
“U”
- This command is sent to the scale to toggle among the configured units.
B.3 TRANSMIT APW MODE
The Transmit APW Mode is designed specifically for connection to any of the following TC
Series scale models:
•
S-630
•
S-650
•
•
Its purpose is to allow APW’s derived on the 304-BP precision balance to be
transmitted to a larger scale for actual piece counting there. Just press the PRINT
key at any time on the 304-BP to initiate the transmission. Consult your S-630, or S-