beautypg.com

Salter Brecknell 304BP User Manual

Page 15

background image

15

NAME/CODE

DESCRIPTION

CODE/VALUE

A1

Baud Rate

Selects the baud rate for data transmission through the serial port.

600

1200 2400

4800

9600

√√√

A2

Data Bits and

Parity

Selects the number of data bits and parity of serial transmission.

"8n" = 8 data bits with no parity bit and one stop bit

"7O" = 7 data bits with odd parity bit and one stop bit

"7E" = 7 data bits with even parity bit and one stop bit

8n

√√√

7O

7E

A3

Mode of Serial

Transmission

Selects when data will be sent out of the serial port to a printer or

computer:

"C" = Continuous mode; send data continuously

"d" = Demand mode; send data when a PRINT command is issued

from the computer.

C

d

√√√

A4

Display Check

Actuates the function that illuminates all digit segments, decimal

points, and LCD annunciators in a test sequence. Pressing the

SAMPLE

key to scroll down one level begins the test sequence.

Press

SAMPLE

key to begin

sequence

A5

Auto Power Off

Period

Selects the auto off time period in minutes. Scale must be idle during

this period to shut off automatically.

"OFF" = Feature Disabled

OFF

√√√

1

5 10

15 20

30

A6

Units Selection

Actuates the function that allows customization of the displayed

weight units. Pressing the

SAMPLE

key to scroll down one level

begins the sequence.

Press

SAMPLE

key to begin

sequence

A7

Custom Unit

Actuates the function that allows setup of the custom unit. Pressing

the

SAMPLE

key to scroll down one level begins the sequence.

Press

SAMPLE

key to begin

sequence

A8

Serial Port

Mode

Selects the mode of the RS-232C serial port:

"0" = Full Duplex Mode

"1" = APW Transmit Mode

0

√√√

1

Table 5-1: User Menu Chart

5.2.4 UNITS SELECTION PROCEDURE (A6)

1. While in the A6.sub-menu, press the SAMPLE key. The scale illuminates the lb

annunciator and displays the current status (ON or OFF) of the lb unit.

2. Use the M+ key to toggle the status of the unit from ON to OFF.
3. Use the ZERO key to toggle among the available weight units.
4. Repeat Steps #2 and #3 until you have programmed all units.
5. Press the PRINT key to save all of your new settings and return back to the A6