beautypg.com

Salter Brecknell 304BP User Manual

Page 20

background image

20

6.2 USING CALIBRATION ADJUSTMENT

1.

This is an after scale calibration function. Be sure to have completed either single or multi

point calibration procedures before proceeding. This is not a substitution for scale calibration

but is a fine tuning tool to make small compensation adjustments.

2.

Experienced service technicians may use the calibration adjustment feature to make fine

adjustments for critical applications.

3.

Refer the to the “F” menu procedures and use F24.

4.

Press the DOWN ARROW key.

5.

The scale shows a regular scale display.

6.

Place a test weight on the scale and view the results.

7.

If the weight is slightly off, press the PRINT key and the right most digit blinks.

8.

Use the UP or DOWN arrow key to adjust the digit.

9.

Press SAVE to store and return to F24.

10.

Repeat procedure with additional weight to adjust linearity.