Salter Brecknell 304BP User Manual
Page 13
13
CHAPTER 5: SCALE CONFIGURATION
5.1
SCALE CONFIGURATION OVERVIEW
The scale contains two main setup menus: The User (“A”) menu - which configures the
serial communication port and enables some user options - and the Factory Setup (“F”)
menu. Both menus consist of several menu selections, each with its own sub-menu of choices.
5.2
USER (“A”) MENU
5.2.1 ENTERING THE USER MENU
1. Turn OFF the scale.
2. Press and hold the UNITS key while turning the scale back ON.
3. When the scale shows “- - - - - -“, you may release the UNITS key. The scale
shows
“A 1”.
5.2.2 NAVIGATING IN THE USER MENU
Use the directional keys shown in Figure 5-1 to move around in the User Menu Chart
shown in Figure 5-2 on the following page.
1. To move to a new “A” heading, use the M+ (left) or MR (right) key to move right or
left in the User Menu Chart.
2.
To move to the selection level, press the SAMPLE (down) key once. The
current saved selection is shown.
3.
To view the available selections for the current “A” heading, use the M+ (left)
or MR (right) key to move through the selection field.
4.
To save a new selection, press the PRINT (Save) key .To exit without saving,
press the ZERO (up) key to return to the current “A” heading.
5.
Repeat Steps 2 through 5 until the User Menu is programmed.
Figure 5-1: User Menu Key Assignments