5.2.5 CUSTOM UNIT PROCEDURE (A7)

The custom unit multiplier is the conversion factor that you would multiply grams

by in order to obtain the custom unit of weight. For example, if you wish to display

weight in troy ounces, you would enter in a multiplier value of 0.64301 ( 1 g =

0.64301 ozt). The scale automatically determines the proper display increment for

your custom unit.

1.

While in the User Menu, scroll to "A 7", then scroll down once using the

SAMPLE key to enter the custom unit multiplier menu.

2. The display will momentarily show "C U" for the custom unit, followed by the

current value for the custom unit multiplier with the decimal point.

3. Use the left or right directional keys (shown in Figure 5-1 above) to move the

decimal point position to the correct position. Pressing the M+ key or the MR

key will change the position of the decimal point.

4. After setting the correct decimal point position, press the PRINT key to save

it.

5. The display will momentarily show "SET", followed by a value with one

flashing digit. This value will be the current multiplier value with the decimal

point position programmed above.

6. Use the four directional keys (shown in Figure 5-1 above) to adjust the

displayed value to the actual custom unit multiplier value. Increase the

flashing digit by pressing the ZERO key. Decrease the flashing digit by

pressing the SAMPLE key. Pressing the M+ key or the MR key will change

the position of the flashing digit.

7. After setting the exact value, press the PRINT key to save the custom unit

multiplier value. The display will show "EndCU" momentarily, then revert

back up to A7.

5.2.6 EXITING THE USER MENU

1. Exit the User (“A”) menu by first turning the scale OFF, then turning it back ON

without holding down any keys. The display will go through a digit check, then

settle into Normal Operating mode. All front panel keys will now return to their normal

mode of operation.

5.3

FACTORY SETUP (“F”) MENU

To enter the “F” menu, power down the scale. Press and hold the PRINT key while

powering on the scale until the scale displays a row of dashes (------) and beeps. Release

the PRINT key. Scale now displays F1. Use the left and right arrow keys to move to another

F number. Use the down arrow key to enter the F number. Use the left and right arrow keys

to view and select the choices. Press SAVE button to accept choice. Use up arrow key to

return to F menu.

To exit F menu, power off scale. Power on scale.

Refer to the “F” menu flow diagram and table for more information.