4.2

CLEARING THE PIECE COUNT

1. To clear the piece count, press the SAMPLE key to take a new sample.

4.3

MEMORY ACCUMULATOR

Your scale comes equipped with a handy memory accumulator, which can be used in

conjunction with the piece counting feature. As with a hand-held calculator, the memory

accumulator can be added to, displayed and cleared at anytime.

NOTE:

This feature can be used in any weighing mode. However, the accumulator memory

is automatically cleared if the scale is switched to another unit of measure using the UNITS

key.

4.3.1

DISPLAYING THE MEMORY ACCUMULATOR

1. Press the MR key. The scale briefly displays the total value stored in the

accumulator but only if the Mem annunciator is lit.

NOTE:

If a device is connected to the scale’s serial port, then that device will

receive an automatic printout of the number of entries made and as well as

the total value stored in the accumulator. See Appendix B for more detailed

information.

4.3.2

ADDING TO THE MEMORY ACCUMULATOR

1.

Press the M+ key. The scale shows “Add”, lights the Mem annunciator,

and then adds the current value shown on the display to the memory

accumulator.

NOTE:

If a device is connected to the scale’s serial port, then that device will

receive an automatic printout of that entry. See Appendix B for more detailed

information.

4.3.3

CLEARING THE MEMORY ACCUMULATOR

1.

Press the MC key. The scale displays “Clr” to indicate that the memory has been

cleared and also extinguishes the Mem annunciator.

4.4

PERCENTAGE MODE

This mode is used to indicate the weight percentage of an item you have placed on the

scale’s platform relative to 100%. This is useful for filling and moisture determination

applications.

The scale uses the sampling method to determine the percentage value of 100%. Consult

Table 4-3 and Table 4-4 for acceptance criteria.

1. Press the UNITS key until the scale is in percentage mode, indicated by the % sign. The

scale should display “100 0 %”. If it does not, press the SAMPLE key.

2. If the items you will be counting require a container, you must first tare the container off by

pressing the ZERO key.

3. Place the reference item (100%) on the platform. Once the scale stabilizes, the scale will

display “100 – %”.