Stardance direct vent - rear vent gas heaters, Wall and ceiling clearances, Mantel clearances – Vermont Casting SDDVRBS User Manual

Page 7: Hearth requirements

background image

7

Stardance Direct Vent - Rear Vent Gas Heaters

20012950

ST128a

SDVR

flue centerline

10/9/00 djt

C

L

18���"

(476mm)

2���"

(63mm)

"

(102 mm)

"

(102 mm)

ST128a

Parallel Installation: Minimum Clearance

and Flue Centerline

Fig. 3 Parallel installation, minimum back and side clearance.

ST129a

stardance

corner specs

10/9/00 djt

Max. Vent

Length

20" (508mm)

7¹⁄₂"

(190mm)

2" (50mm)

2"

(50mm)

ST129a

Corner Installation: Minimum Clearance

and Flue Centerline

Fig. 4 Corner installation, minimum corner clearance and flue
centerline.

ST381a

SDVR

clearance diagram

10/9/00 djt

9"

(230mm)

Max. Mantel

Width

See

Fig. 6

6"

(150mm)

Sidewall/

Trim

2���"

(63mm)

Rear Wall

ST381a

Wall and Ceiling Clearances

Fig. 5 Clearances to ceiling or alcoves.

Mantel Clearances

Noncombustible

Materials

ST382

Pinnacle

mantel clearances

6/13/00 djt

A

B

3" (75mm) Min.

ST382

A = Depth of Mantel and/or Top Trim
B = Height from Top of Heater

A (Max.)

B (Min.)

9”

10¹⁄₂”

(230 mm)

(270 mm)

7¹⁄₂”

9”

(190 mm)

(230 mm)

6”

7¹⁄₂”

(152 mm)

(190 mm)

4¹⁄₂”

6”

(114 mm)

(152 mm)

3”

4¹⁄₂”

(76 mm)

(114 mm)

1¹⁄₂”

3”

(38 mm)

(76 mm)

Fig. 6 Mantel / top trim clearances.

Combustible

Mantel or Trim

Materials

Hearth Requirements

The Stardance Heater must be installed on rigid floor-
ing. When the heater is installed directly on any com-
bustible surface other than wood flooring, a metal or
wood panel extending the full width and depth of the
unit must be used as the hearth. There are no other
hearth requirements.