beautypg.com

Stardance direct vent - rear vent gas heaters – Vermont Casting SDDVRBS User Manual

Page 40

background image

40

Stardance Direct Vent - Rear Vent Gas Heaters

20012950

CO106a

DV360/580

Gas Conversion

Pilot2

1/28/00 djt

Index Tab

Snap Ring

Allen Wrench

CO106a

Fig. 71 Remove pilot orifice.

CO105a

gas conversion

Pilot

1/28/00 djt

Pilot Hood

Pilot

Bracket

CO105a

Fig. 70 Remove pilot hood.

3. Remove motor top cap using a standard slotted

screwdriver. Depress and turn center plunger until
arrow points to correct screw. Red for LP and Blue
for NG. NOTE: Plunger will “snap” into NG position
when arrow is close to blue screw. It will not “snap”
at LP (Red) position. (Fig. 68)

FP1037b

comfort valve

convert

3/6/01 djt

LOCAL

REMO

TE

O

N

PILO

T

OFF

LED

Center

Plunger

Motor Top Cap

Red - LP

Blue - NG

FP1037b

Fig. 68 Depress and turn center plunger.

Valve

4. Insure manifold pressure remains between 3.2” - 3.5”

w.c. for NG and 9.5” - 10” w.c. for LP. To adjust the
manifold pressure, for NG, using a Torx #10 key turn
the blue screw clockwise to increase the manifold
pressure. Turn the screw counterclockwise to de-
crease the pressure. Use the red screw to adjust LP.

5. Replace motor top cap.
Pilot Orifice Conversion
1. Locate pilot. (Fig. 69)

ST935

SDDVT

pilot location

6/07

ST935

Fig. 69 Pilot assembly location.

2. Replace pilot orifice.
Pilot Type 1
• Remove pilot hood by lifting up. (Fig. 70) Do not

remove snap ring to remove pilot hood. NOTE: It is
not necessary to remove the pilot tube for conver-
sion.

• Remove pilot orifice with Allen wrench. (Fig. 71)
• Install the conversion orifice.

CO142

Rf pilot Conversion

6/07 djt

Pilot Hood

Index

Marks

Pilot Bracket

CO105

Fig. 72 Remove pilot hood. (Your pilot may have a different
appearance.)

CO144

RF Pilot conversion

6/07 djt

Pilot

Orifice

CO106b

Fig. 73 Remove pilot orifice.

• Reinstall pilot hood. Be sure to align hood with

index tab.

Pilot type 2
• Loosen pilot hood turning counterclockwise using a

7/16” wrench. (Fig. 72) NOTE: You may use pen-
etrating oil to prevent pilot hood threads from seizing
up.

• Remove pilot orifice with needlenose pliers. (Fig.

73) NOTE: Use a wrench to hold pilot tube in place
while removing the orifice.

• Install the conversion orifice.
• Reinstall pilot hood and tighten until mark on pilot

hood aligns with mark on pilot bracket.