beautypg.com

Installation & operating instructions – Vermont Casting SDDVRBS User Manual

Page 3

background image

3

Stardance Direct Vent - Rear Vent Gas Heaters

20012950

The Stardance Direct Vent Room Heater, Models. SDDVR Series:
SDDVRCB, SDDVREB, SDDVRMB, SDDVRBS, SDDVRCH, SD-
DVRVG, SDDVRBD; SDDVRC Series: SDDVRCCB, SDDVRCEB,
SDDVRCMB, SDDVRCBS, SDDVRCCH, SDDVRCVG, SDDVR-
CBD are vented gas appliances listed to ANSI Standard Z21.88-
2005 and CSA-2.33-2005 for Vented Room Heaters, and CSA
2.17-M91, Gas-Fired Appliances For Use at High Altitudes.
The installation of the Stardance Direct Vent Room Heaters must
conform with local codes, or in the absence of local codes, with
National Fuel Gas Code, ANSI Z223.1/NFPA 54 — latest edition
and CSA B-149.1 (EXCEPTION: Do not derate this appliance for
altitude. Maintain the manifold pressure at 3.5” w.c. for Natural
Gas and 10” w.c. for LP gas at maximum input.) Refer to Page
7 (RF only).
This appliance is only for use with the type of gas indicated on the
rating plate. This appliance is not convertible for use with other
gases unless a certified kit is used.
Installation and replacement of gas piping, gas utilization
equipment or accessories, and repair and servicing of equip-
ment shall be performed only by a qualified agency, preferably
NFI or WETT (Canada) certified. The term “qualified agency”
means any individual, firm, corporation, or company that
either in person or through a representative is engaged in
and is responsible for (a) installation or replacement of gas
piping, or (b), the connection, installation, repair, or servic-
ing of equipment, who is experienced in such work, familiar
with all precautions required, and has complied with all the
requirements of the authority having jurisdiction.
The Stardance Direct Vent Room Heaters should be inspected
before use and at least annually by a qualified service agency.
It is imperative that control compartments, burners, and cir-
culating air passageways of the appliance be kept clean.
The Stardance Direct Vent Room Heaters and the individual shut-
off valve must be disconnected from the gas supply piping during
any pressure testing of that system at test pressures in excess
of 1/2 psig (3.5 kPa).
The Stardance Direct Vent Room Heaters must be isolated from
the gas supply piping system by closing the individual manual
shutoff valve during any pressure testing of the gas supply piping
system at test pressures equal to or less than 1/2 psig.
An accessible tap is located above the pilot/on-off knob for check-
ing the inlet pressure.
‘Direct Vent’ describes a sealed combustion system in which in-
coming outside air for combustion and outgoing exhaust enter and
exit through two separate concentric passages within the same
sealed vent system. The system does not use room air to support
combustion. The Direct Vent system permits the gas appliance to
be vented directly to the outside atmosphere through the side of
the house or vertically through the roof.
This appliance is approved for bedroom installations in the U.S.
and Canada.
This appliance may be installed in an aftermarket* manufactured
(mobile) home, where not prohibited by state or local codes.
WARNING: Operation of this heater when not connected to a
properly installed and maintained venting system can result
in carbon monoxide (CO) poisoning and possible death.

The Stardance Direct Vent Room Heater, when installed, must
be electrically grounded in accordance with local codes or, in the
absence of local codes, with the National Electrical Code ANSI/
NFPA 70, (latest edition), or of the current Canadian Electrical
Code C22.1.
Due to high temperatures this appliance should be located
out of traffic and away from furniture and draperies.
WARNING: This appliance is hot while in operation. Keep
children, clothing, and furniture away. Contact may cause
burns or ignition of combustible materials.
Children and adults should be alerted to the hazards of high
surface temperatures and should stay away to avoid burns or
clothing ignition. Young children should be carefully super-
vised when they are in the same room as the appliance.
Clothing or other flammable materials should not be placed
on or near the appliance.
Any safety screen, glass or guard removed for servicing an ap-
pliance must be replaced prior to operating the appliance.
The appliance area must be kept clear and free from com-
bustible materials, gasoline, and other flammable vapors
and liquids.
The flow of combustion and ventilation air must not be ob-
structed. The installation must include adequate accessibility
and clearance for servicing and proper operation.
WARNING: Do not operate the Room Heater with the glass
panel removed, cracked or broken. Replacement of the panel
should be done by a licensed or qualified service person.
Do not use this appliance if any part has been under water.
Immediately call a qualified service technician to inspect the
appliance and to replace any part of the control system and
any gas control which has been under water.
Do not burn wood, trash or any other material for which this
appliance was not designed. This appliance is designed to
burn either natural gas or propane only.
This gas appliance must not be connected to a chimney flue
serving a separate solid-fuel burning appliance.
CAUTION: Label all wires prior to disconnection when servic-
ing controls. Wiring errors can cause improper and danger-
ous operation.
Verify proper operation after servicing.
* Aftermarket:
Completion of sale, nor for purpose of resale,
from the manufacturer.

Installation & Operating Instructions

Proposition 65 Warning: Fuels used in gas, woodburning or
oil fired appliances, and the products of combustion of such
fuels, contain chemicals known to the State of California to
cause cancer, birth defects and other reproductive harm.
California Health & Safety Code Sec. 25249.6

Stardance Direct Vent / Rear Vent

Certified to:

ANSI Z21.88-2005 / CSA Z2.33-2005

Vented Gas Fireplace Heaters