Stardance Direct Vent - Rear Vent Gas Heaters
20012950
�����
������������������
����
Vent Termina-
tion (VC)
Storm Collar
(SC)
Roof Flash-
ing (AF)
Ceiling Support
(CS)
Trim Plate
(TP)
Pipe Length
Pipe Length
Appliance Adapter
(AAV)
90° Elbow
(EL90)
Fig. 39 Selkirk venting
components.
ST945
�����
���������������
����
Pipe
Length
Appliance
Adapter (AAV)
Trim Plate (TP)
(Required if Wall
Thimble is not used)
Wall Thimble (WT)
(Optional)
Horizontal Ter-
mination (HC)
ST946
A two-part square trim plate is provided to give a fin-
ished look once installed. Simply fit the two halves of
the trim plate around the cathedral ceiling support box
hanging below the ceiling (overlapping if necessary)
and screw them to the ceiling. Both the ceiling support
and cathedral ceiling support can support a maximum
of 40’ (12 m) of pipe.
Offsets:
If any offsets are necessary in the vertical system, an
Offset Support (OS) should be installed directly above
the upper elbow of the offset. Install by attaching the
offset support band to the pipe with two #8 x 1/4” sheet
metal screws (minimum ) and secure the offset support
straps to surrounding structure. (Fig. 40)
�����
��������������������
����
Nail to top of
framing
Offset Support
Strap
Offset Support
Collar
ST927
Fig. 40 Offset support.