Page 33: Stardance direct vent - rear vent gas heaters

background image

33

Stardance Direct Vent - Rear Vent Gas Heaters

20012950

3. Open control access panel.
4. Push in gas control knob slightly and turn clock-

wise

to “OFF”. Do not force.

5. Close control access panel.

1. STOP! Read the safety information above.
2. Turn off all electrical power to the fireplace.
3. Turn the On/Off switch to “OFF” position, set

the remote to OFF or set thermostat to lowest
level.

4. Open control access panel.
5. Push in gas control knob slightly and turn

clockwise

to “OFF”.

10. Push the control knob all the way in and hold.

Immediately light the pilot by repeatedly depress-
ing the piezo spark ignitor until a flame appears.
Continue to hold the control knob in for about one
(1) minute after the pilot is lit. Release knob and it
will pop back up. Pilot should remain lit. If it goes
out, repeat steps 5 through 8.

FOR YOUR SAFETY READ BEFORE LIGHTING

• If you cannot reach your gas supplier, call the

Fire Department

C. Use only your hand to push in or turn the gas

control knob. Never use tools. If the knob will not
push in or turn by hand, do not try to repair it, call a
qualified service technician. Applying force or any
attempted repair may result in a fire or explosion.

D. Do not use this fireplace if any part has been under

water. Immediately call a qualified service techni-
cian to inspect the heater and to replace any part of
the control system and any gas control which has
been under water.

A. This heater has a pilot which must be lit manu-

ally. When lighting the pilot follow these
instructions exactly.

B. BEFORE LIGHTING smell all around the heater

area for gas. Be sure to smell next to the floor
because some gas is heavier than air and will
settle on the floor.

WHAT TO DO IF YOU SMELL GAS
• Do not try to light any fireplace
• Do not touch any electric switch
• Do not use any phone in your building
• Immediately call your gas supplier from a neigh-

bor’s phone. Follow the gas supplier’s instruc-
tions.

To Turn Off Gas To Heater

Lighting And Operating Instructions

1. Turn the On/Off switch to Off position or set the

thermostat to lowest setting.

2. Turn off all electric power to the fireplace if

service is to be performed.

Lighting Instructions

6. Remove glass door before lighting pilot. (See

Glass Frame Removal section).

7. Wait five (5) minutes to clear out any gas. Then

smell for gas, including near the floor. If you
smell gas, STOP! Follow “B” in the safety infor-
mation above. If you do not smell gas, go to the
next step.

8. Visibly locate pilot by the main burner.
9. Turn knob on gas control counterclockwise

to “PILOT”.

• If knob does not pop up when released, stop

and immediately call your service technician or
gas supplier.

• If after several tries, the pilot will not stay lit,

turn the gas control knob to “OFF” and call your
service technician or gas supplier.

11. Replace glass door.
12. Turn gas control knob to “ON” position.
13. Turn the On/Off switch to “ON” position or set

thermostat to desired setting.

14. Turn on all electrical power to the fireplace.

WARNING:If you do not follow these instructions exactly, a fire or explosion

may result causing property damage, personal injury or loss of life.

Euro SIT

SIT NOVA

Honeywell

�����

��

���

��

PILOT

O

FF

OFF

FP1067

lighting instruction

knobs

3/9/01 djt

5

4

3

2

1

OF

F

Pi

lo

t

3/8" - 1/2"

FP1068

Lighting instructions

Pilots