Stardance direct vent - rear vent gas heaters, Fireplace installation requirements – Vermont Casting SDDVRBS User Manual
Page 21
21
Stardance Direct Vent - Rear Vent Gas Heaters
20012950
ST379a
SDVR
Min. fireplace installation
6/00
26"
(660mm)
16"
(406mm)
ST379a
Transition
Connector
Fig. 34 Minimum lintel height for flush or forward placement.
26"
(660mm)
20���"
(521mm)
ST380a
SDVR
min. lintel height
6/00
ST380a
Transition
Connector
Fireplace Installation Requirements
6"
(152mm)
20¹⁄₂"
(521mm)
ST713a
SDVR
existing stove chimney
3/02
26"
(660mm)
*
Existing Wood Stove
Chimney Pipe
Finished Combus-
tible Wall
ST713a
* Transition pipe must be at least 6” (152
mm) from any combustible material.
Fig. 35 Installations using existing wood stove chimney pipe.
ST714
SDVR
thru fireplace
chimney wall
4/02
X
Existing Vent Pipe
Transition Connector
Field
Fabricated Cover
ST714
“X” must be 6” (152 mm) from any combustible material un-
less completely covered by field fabricated sheet metal. If
3” vent pipes are covered by sheet metal, the clearance to
combustibles may be 2” (51 mm).
Fireplace Installations Using Existing Wood Stove Chimneys