Vermont Casting SDDVRBS User Manual
Page 28
28
Stardance Direct Vent - Rear Vent Gas Heaters
20012950
Thermostat
Wire / Gauge
Maximum Run
18
40 feet
20
25 feet
22
16 feet
Thermostat Connection
(Optional) R Models Only
Use only a thermostat rated for 500 - 750 millivolts.
Check the table below for the appropriate gauge
thermostat wire to use for the length of lead required in
your installation.
1. Install the wall thermostat in the desired location and
run the wires to the stove location. Terminate these
leads with 1/4” female connectors.
2. Connect the thermostat wires to the valve. (Fig. 49)
This completes assembly of the Stardance Rear
Vent stove.
Install the Front Plate
Grasp the Front Plate and lift it into position, engaging
the two steel tabs at the upper corners behind the adja-
cent bosses in the Side Plates. (Fig. 50) Seat the Front
against the Sides so that the tabs at the bottom lip
engage with the notches in the edge of the stove base.
When properly installed, the bottom of the Front Plate
cannot be pulled away from the sides without also lifting
it up.
If you are installing optional Warming Shelves, do so
now, according to the instructions supplied with that kit.
ST228
attach switch
wires to valve
12/99
PILO
T
ADJ
TP
TH
TPTH
ST228
Fig. 49 Attach switch wires to valve.
ST940
Stardance
Remove Front
6/07
Fig. 50 Install Stove Front.
ST940
Bottom Tabs
Engage Notch in
Base