beautypg.com

2 point-to-multipoint pvcs, Point-to-multipoint pvcs -2 – Cabletron Systems 6500 User Manual

Page 80

background image

6-2 SmartSwitch 6500 User Guide

PVC Connections

Virtual Ports and Static Connections

For this example, we specify CBR as the traffic type, then take the remaining defaults. Enter the

show

trafficdescriptor

command to obtain the index number of the new traffic descriptor. In this example, the index

number is two (2).

Smart6500 # show trafficdescriptor

========================================================================================

TD# Traff Desc QoS Peak Cell Rate Sust Cell Rate Max Burst Size Min Cell Aal Type

Type Type (Kb/s) (Kb/s) (Kb/s) Rate

CLP_0 CLP_0+1 CLP_0 CLP_0+1 CLP_0 CLP_0+1 (Kb/s)

=========================================================================================

1 NRTVBR 7 0 0 10872 5436 0 2052 0 0 5

2 CBR 2 1 0 100 0 0 0 0 0 5

176 NRTVBR 2 1 0 1585 0 0 0 0 0 5

Smart6500 #

2.

Use

add pvc

to create the PVC; specify the ports through which the connection is established, the

VPI/VCI pair to use with each port, and the traffic descriptor to use.

Smart6500 # add pvc

ConnType(PTP) :

Port-1-Number() : 7a1

< Specify first port

Port-1-VPCI() : 0

< Specify its VPCI

Port-1-VCI() : 100

< Specify its VCI

Port-2-Number() : 7b2

< Specify second port

Port-2-VPCI() : 0

< Specify its VPCI

Port-2-VCI() : 100

< Specify its VCI

Port1-to-Port2TrafficDescriptorIndex() : 2

< We use our traffic descriptor

Port2-to-Port1TrafficDescriptorIndex() : 2

Smart6500 #

The example above creates a PVC between ports 7a1 and 7b2 with VPCI/VCI = 0/100.

3.

Plug the end nodes into the specified SmartSwitch 6500 ports (7a1 and 7b2).

4.

Configure each end node with the proper IP address, subnet mask, and VPCI/VCI pair = 0/100.

The end nodes can communicate with each other through the point-to-point PVC connection.

6.1.2

Point-to-Multipoint PVCs

Instructions in this section describe how to set up a point-to-multipoint connection through your SmartSwitch 6500.

Example: Create a point-to-multipoint connection between a broadcasting workstation on port 7a1 and three other
workstations connected to ports 7a2, 7a3, and 7a4.

1.

Use

add trafficdescriptor

to create two new traffic descriptors, one for the forward direction, the

other for the backward direction. For this example, for the forward traffic descriptor, we select UBR
and accept the defaults.

Smart6500 # add trafficdescriptor

< This is the forward descriptor

TrafficType(UBR) :

< We use UBR for this example

TrafficDescriptorType(11) :

PCRCLP01(100) :

< Take the default values

QOSCLASS(0) :

AalType(5) :

Smart6500 #