Connecting through the drac/mc, Connecting through the – Cisco 3030 User Manual
Page 37
2-9
Cisco Catalyst Blade Switch 3030 Hardware Installation Guide
OL-8389-01
Chapter 2 Switch Installation
Installing the Switch Module into the Server Chassis
Step 3
Configure the baud rate and character format of the PC or terminal to match these console port default
characteristics:
•
9600 baud
•
8 data bits
•
1 stop bit
•
No parity
•
None (flow control)
Step 4
Go to the
“Waiting for POST to Complete” section on page 2-11
to finish configuring the switch module.
Connecting through the DRAC/MC
Follow these steps when connecting through the DRAC/MC:
Step 1
Connect one end of a DB9 null-modem or crossover cable to the RS-232 console serial port of the
DRAC/MC. Connect the other end of the cable to the RS-232 console serial port of the computer. (See
Note
The default data rate of the DRAC/MC console serial port is 115200 baud.
Figure 2-5
Connecting through the DRAC/MC Serial Port
148377
11x
12x
13x
14x
15x
16x
Console
11x
12x
13x
14x
15x
16x
CON