Tomei Powered EXHAUST MANIFOLD User Manual
Page 13

- 13 -
【Verification】
Please ensure that the cylinder head is free from any oil leaks from the bottom stud where the original exhau
st manifold is connected to. If there are signs of leaks, please remove the head, stud,
double nut and the screw lock to repair the leak..
After removing the studs please take care
and cover the holes to prevent any foreign
objects from entering the holes.
Check all 5 points
【
】
Installation Procedure
1.
Please decide if you want to use the Thermal Bandage that has been included in the kit and or to retain
(sold seperately Part No. 191247).
the genuine heat sheild or if you would like to use the Tomei heat sheild
】
【Applying the Thermal Bandage
Wrap around the ehaust manifolds pipes covering as much as possible and
secure in place with the bandage band clips provided.
・Soak the Bandage in water, then wring the excess water out prior to use.
・After applying the bandage, please cut off any unwanted excess bandage
after the manifold is completely covered.
2. Fit the TOMEI exhaust manifold gasket to the cylinder head prior to fitting the exhaust manifold
(Page 4 illustration ①).
【Tightening】
29 Nm (2.9 kgf-m)
・Tighten in the order as shown in the
3
4
5
6
illustration. on the left..
1
7
9
8
2
49 Nm (4.9kgf-m)
29 Nm (2.9kgf-m)
49 Nm (4.9kgf-m)
3. Fit the exhaust manifold gasket that is supplied in the kit (Page 4 illustration #②) and then fit the turbo
[Torque Settings 59Nm (5.9kgf-m)]
charger.