beautypg.com

Exam ple, K404a, Caution – Qmark LFK Series - Wall Heater User Manual

Page 4

background image

Operation

1. Turn power to heater on at main switch panel. Rotate the

thermostat knob fully clockwise. This should energize the

heating elements and the fan, causing air to flow from the

air discharge at the openings in the bottom of the grille.

2. After the discharge air has become warm, rotate the

thermostat knob to the desired postion to obtain room

comfort.

NOTE: For best results, the heater should be left ON con-

stantly during the heating season since the thermostat, when

properly set, will maintain the desired temperature.

IMPORTANT INFORMATION

Maintenance

TO RESET MANUAL RESET LIMIT

Your heater is equipped with a manual reset safety thermal

limit control that will automatically turn the heater off to pre-

vent a fire if the heater overheats. This control is located on

the fan panel assembly between the element and fan blade

and marked “reset”. The red reset button can be seen

through the front grille when the heater is installed. To reset,

allow the heater to cool, then push the red button that is vis-

ible through the hole in the fan panel. The heater should

immediately return to normal operation.

The heater should be cleaned annually to remove dust and

other foreign material which has collected during the heating

season. This is a simple operation when performed as fol-

lows:

1. Turn off the electric power at main line switch (or

remove all fuses) to disconnect electric power from the

heater. THIS IS IMPORTANT.

2. Remove the grille (Fig. 4).

3. With a vacuum cleaner nozzle or dust cloth, remove

dust and other foreign material.

4. After cleaning reinstall the grille.

5. Turn on the main line switch (or replace fuses) to

restore power to the heater. The heater is now ready

for another season of operation.

MODEL NO.

K404A

DATE CODE:

0595

FAN FORCED WALL HEATER

APPAREIL DE CHAUFFAGE MURAL À AIR PLUSÉ

VOLTS AC

60HZ

WATTS

PHASE

240/208

4000/3000

1

MUST BE USED WITH BACK BOX

DO NOT OPERATE WITHOUT FRONT COVER IN

PLACE.

DOIT ÉTRE UTILISÉ AVEC BOÎTIER ARRIÈRE AWH-BB

NE PAS UTILISER SI LE COUVERCLE AVANT NʼEST PAS EN PLACE.

MARLEY ENGINEERED PRODUCTS

BENNETTSVILLE, SC 29512

4104-2093-028

774G LISTED

ROOM HEATER

CAUTION

!

CAUTION

!

OPERATION OF THE MANUAL RESET SAFETY THERMAL LIMIT

CONTROL IS AN INDICATION THAT THE HEATER HAS BEEN

SUBJECTED TO SOME ABNORMAL CONDITION. IT IS RECOM-

MENDED THAT THE HEATER BE CHECKED BY A REPUTABLE

ELECTRICIAN OR REPAIR SERVICE TO ENSURE THE HEATER

HAS NOT BEEN DAMAGED.

DO NOT USE WATER OR DAMP CLOTH FOR CLEANING

AND DO NOT DISTURB THE HEATING ELEMENT.

4

EXAM

PLE