beautypg.com

Conduit mounting (indoor or outdoor), Wiring, Installation of quartz lamp element – Qmark FRP/FRS - 2 & 3 Element Infrared Heaters User Manual

Page 3

background image

Conduit, conduit connectors, and fasteners to secure heater
to ceiling are supplied by others in the following instructions.

1. On a workbench or other flat surface, attach mounting

brackets to ends of wireway cover (see Figure 4A) using
bolts, star washers, and nuts supplied.

2. Remove screws (see Figure 4) from front of wireway

cover, rotate wireway cover back, and remove from wire-
way base.

3. Mount wireway cover/mounting brackets to ceiling and

secure using fasteners (by others) sized to sufficiently sup-
port heater and any optional accessories used.

4. Remove knockout from top or either end of wireway cover

and install conduit connector and conduit.

5. Route supply wire to heater.
6. Align "T" tabs on wireway base with slots in wireway cover

and hang heater assembly on wireway cover. Allow to
hang open.

7. Proceed to wiring section (see Figure 6).

Conduit Mounting (Indoor or Outdoor)

Refer to Figure 5 and proceed as follows.

Conduit and conduit connectors supplied by others in the fol-
lowing instructions.

1. Do not attach supplied mounting brackets.
2. Mount field supplied conduit to building structure, secure

using fasteners (by others) sized to sufficiently support
heater and any optional accessories used.

3. Route supply wire to heater.
4. Remove screws (see Figure 5) from front of wireway cover,

rotate wireway cover back, and remove from wireway
base.

5. Remove knockout from top of wireway cover and attach

wireway cover to conduit connector and conduit.

6. Align "T" tabs on wireway base with slots in wireway cover

and hang heater assembly on wireway cover. Allow to
hang open.

7. Proceed to wiring section (see Figure 6).

Wiring

Refer to Figure 6 and proceed as follows.

1. Connect heater wiring to power supply wiring as shown in

Figure 6.

2. Connect the power supply ground wire to the heater green

grounding lead wire.

3. Carefully fold the wires into the wiring compartment so

they will not be pinched by the wiring compartment cover.

4. Pivot the heater assembly until the wiring compartment

base rotates into place in the wiring compartment.

5. Secure the wiring compartment cover to the base with the

screws removed previously.

Installation of Quartz

Lamp Element

1. Remove terminal cover at each end of fixture to gain

access to terminal blocks. Loosen #10 hex nut on terminal
stud. Then wrap element lead around terminal one full turn
as shown in Figure7. Tighten nut, making sure there is
some slack in the lead after the attachment is made. Cut
off and discard extra wire.

3

screws for wiring

Remove

Wireway cover

Conduit &
Connector

1/4 (Min)
Solid Steel Rod
Typical 4 Places

Figure 5

Single Stage Control

Two Stage Control

Thermostat

(Field Supplied)

2 Stage

SUPPLY POWER

ELEMENT 1

ELEMENT 2

3

1

4

2

SUPPLY POWER

ELEMENT 2

ELEMENT 1

3

1

4

2

Figure 6

Figure 7

Figure 8