Important information, I1500, Caution – Qmark FDI - Floor Drop-In Heaters User Manual

Page 3: Nameplate, Maintenance

background image

Figure 3

Painted

screws

Sheet

metal

screws

(4)

Alarm

Buzzer

(or WarningLight)

Auto Reset

Over-temperature

Limit

Motor

L2 or N(120Volt)

BLACK - 240V/208V

WHITE - 120V

L1

BLACK

One Shot

Thermal

Cutout

(TCO)

Optional Single

Pole Built-in

Thermostat

(Model ITSP)

1

2

1

2

RED

RED

Elements
Heater Wiring

Field Wiring

Optional Single

Pole or Double

Pole Wall

Thermostat

Figure 4

3

IMPORTANT INFORMATION

MAINTENANCE

TO CLEAN HEATER: The heater should be cleaned annually for

maximum efficiency. Before cleaning be sure power is off and

heater is cool. Remove grille and clean fan using a vacuum

cleaner with a brush attachment. The grille may be cleaned with

a slightly damp rag if desired.

OPERATIONAL NOTICE

Your heater is equipped with an automatic reset limit control that

will automatically turn the heater OFF to prevent a fire if the

heater overheats. If the heater overheats, an alarm buzzer (or

light on some models) will sound (or light will illuminate on some

models) until the heater cools and the limit resets.

.

THE ACTIVATION OF THE ALARM BUZZER (OR LIGHT) SIGNIFIES

THE HEATER HAS BEEN SUBJECTED TO SOME ABNORMAL CON-

DITION CAUSING IT TO OVERHEAT. CHECK HEATER TO INSURE

THAT IT HAS NOT BEEN BLOCKED IN ANY MANNER (IF SO,

REMOVE BLOCKAGE). IF THERE IS NO INDICATION OF BLOCK-

AGE IT IS RECOMMENDED THE HEATER BE CHECKED BY A REP-

UTABLE ELECTRICIAN OR REPAIR SERVICE TO INSURE THE

HEATER HAS NOT BEEN DAMAGED.

a

CAUTION

!!

MODEL NO.

I1500

DATE CODE

0997

FAN FORCED FLOOR INSERT HEATER

120

1500/750

12.5/6.3/

VOLTS AC

WATTS

AMPS

USE ONLY WITH I SERIES ENCLOSURE. DO

NOT OPERATE WITHOUT GRILLE IN PLACE.

MARLEY ENGINEERED PRODUCTS

BENNETTSVILLE, SC 29512

4104-2206-000

774G LISTED

ROOM HEATER

NAMEPLATE

In addition to the Automatic control your heater is provided with

a back up one shot thermal cut-out (TCO). This safety control

will open only if the automatic control fails to maintain safe tem-

peratures. If this control operates, your heater must be ser-

viced by a qualified electrician