Warning, Receiving, Specifications installation – Qmark CPH - Decorative and Commercial Pedestal Heaters User Manual
Page 2
RECEIVING
1. Each Pedestal Heater is shipped in two cartons. One carton
contains the heater, the other contains the pedestals.
2. Material when shipped was in good order and Marley
Engineered Products hold clear bill of lading, therefore any
concealed damage must be reported at once to the carrier
for inspection and settlement.
SPECIFICATIONS
INSTALLATION
Note: It is advisable to store cartons in a central area to be
drawn upon as needed per room requirements. If called for on
order, the cartons will have been tagged with proper room
number.
2
Table A
Table A (continued)
Model CPH05A, DPH05A (H=5-1/2”; D=3”)
Catalog
Total
Amperage
Number*
Length
Watts/Ft.
Watts
120V
208V
240V
277V
05A-2125
125
250
2.4
1.2
1.0
0.9
05A-2188
28”
188
375
3.1
1.8
1.6
1.4
05A-2250
250
500
4.2
2.4
2.1
1.8
05A-3125
125
375
3.1
1.8
1.6
1.4
05A-3188
3’
188
564
4.7
2.7
2.4
2.0
05A-3250
250
750
6.2
3.6
3.1
2.7
05A-4125
125
500
4.2
2.4
2.1
1.8
05A-4188
4’
188
750
6.2
3.6
3.1
2.7
05A-4250
250
1000
8.3
4.8
4.2
3.6
05A-5125
125
625
5.2
3.0
2.6
2.2
05A-5188
5’
188
940
7.8
4.5
3.9
3.4
05A-5250
250
1250
10.4
6.0
5.2
4.5
05A-6125
125
750
6.2
3.6
3.1
2.7
05A-6188
6’
188
1125
9.4
5.4
4.7
4.1
05A-6250
250
1500
12.5
7.2
6.2
5.4
05A-8125
125
1000
-
4.8
4.2
3.6
05A-8188
8’
188
1500
-
7.2
6.2
5.4
05A-8250
250
2000
-
9.6
8.3
7.2
05A-10125
125
1250
-
6.0
5.2
4.5
05A-10188
10’
188
1875
-
9.0
7.8
6.7
05A-10250
250
2500
-
12.0
10.4
9.0
Model CPH07A, DPH07A (H=7”; D=5”)
Catalog
Total
Amperage
Number*
Length
Watts/Ft.
Watts
208V
240V
277V
1Ш
3Ш
1Ш
3Ш
1Ш
07A-2125
125
250
1.2
-
1.0
-
0.9
07A-2188
188
375
1.8
-
1.6
-
1.4
07A-2250
250
500
2.4
-
2.1
-
1.8
07A-2375
375
750
3.6
-
3.1
-
2.7
07A-2500
28”
500
1000
4.8
-
4.2
-
3.6
07A-2564
564
1125
5.4
3.1
4.7
2.7
4.0
07A-2625
625
1250
6.0
3.5
5.2
3.0
4.5
07A-2750
750
1500
7.2
4.2
6.2
3.6
5.4
07A-3125
125
375
1.8
-
1.6
-
1.4
07A-3188
188
564
2.7
-
2.4
-
2.0
07A-3250
250
750
3.6
-
3.1
-
2.7
07A-3375
3’
375
1125
5.4
-
4.7
-
4.0
07A-3500
500
1500
7.2
-
6.2
-
5.4
07A-3564
564
1690
8.1
4.7
7.4
4.3
6.1
07A-3625
625
1875
9.0
5.2
7.8
4.5
6.7
07A-3750
750
2250
11.0
6.5
9.4
5.4
8.1
Model CPH07A, DPH07A (H=7”; D=5”) (Cont.)
Catalog
Total
Amperage
Number*
Length
Watts/Ft.
Watts
208V
240V
277V
1Ш
3Ш
1Ш
3Ш
1Ш
07A-4125
125
500
2.4
-
2.1
-
1.8
07A-4188
188
750
3.6
-
3.1
-
2.7
07A-4250
250
1000
4.8
-
4.2
-
3.6
07A-4375
375
1500
7.2
-
6.2
-
5.4
07A-4500
4’
500
2000
9.6
-
8.3
-
7.2
07A-4564
564
2250
10.8
6.2
9.4
5.4
8.0
07A-4625
625
2500
12.0
6.9
10.4
6.2
9.0
07A-4750
750
3000
14.4
8.3
12.5
7.2
10.8
07A-5125
125
625
3.0
-
2.6
-
2.2
07A-5188
188
940
4.5
-
3.9
-
3.4
07A-5250
250
1250
6.0
-
5.2
-
4.5
07A-5375
5’
375
1875
9.0
-
7.8
-
6.7
07A-5500
500
2500
12.0
-
10.4
-
9.0
07A-5564
564
2820
13.5
7.8
11.8
6.8
10.2
07A-5625
625
3125
15.0
8.6
13.0
7.5
11.3
07A-5750
750
3750
18.0
10.4
15.6
9.0
13.5
07A-6125
125
750
3.6
-
3.1
-
2.7
07A-6188
188
1125
5.4
-
4.7
-
4.0
07A-6250
250
1500
7.2
-
6.2
-
5.4
07A-6375
6’
375
2250
10.8
-
9.4
-
8.1
07A-6500
500
3000
14.4
-
12.5
-
10.8
07A-6564
564
3380
16.2
9.4
14.1
8.1
12.2
07A-6625
625
3750
18.0
10.4
15.6
9.3
13.5
07A-6750
750
4500
21.6
12.5
18.7
10.8
16.2
07A-8125
125
1000
4.8
-
4.2
-
3.6
07A-8188
188
1500
7.2
-
6.2
-
5.4
07A-8250
250
2000
9.6
-
8.3
-
7.2
07A-8375
8’
375
3000
14.4
-
12.5
-
10.8
07A-8500
500
4000
19.2
-
16.7
-
14.4
07A-8564
564
4500
21.6
12.5
18.7
10.8
16.2
07A-8625
625
5000
24.0
13.9
20.8
12.4
18.0
07A-8750
750
6000
28.6
16.5
25.0
14.4
21.6
07A-10125
125
1250
6.0
-
5.2
-
4.5
07A-10188
188
1875
9.0
-
7.8
-
6.7
07A-10250
250
2500
12.0
-
10.4
-
9.0
07A-10375
10’
375
3750
18.0
-
15.6
-
13.5
07A-10500
500
45000
24.0
-
20.8
-
18.0
07A-10564
564
5640
27.2
15.7
23.5
13.6
20.4
07A-10625
625
6250
30.0
17.4
26.0
15.0
22.6
07A-10750
750
7500
36.6
20.8
31.3
18.1
27.0
Warning-To reduce the risk of fire, electric shock and damage
to property, read, understand and follow the below special
instructions:
1. All wiring procedures and connections must be in accor-
dance with the National Electrical Code (NEC) and local
codes.
2. Do not install heaters against combustible low-density cellu-
lose fiberboard surfaces.
3. Do not install heaters below electrical convenience recepta-
cles (outlets).
4. To reduce the risk of fire, do not store or use gasoline or
other flammable vapors or liquids in the vicinity of the
heater.
5. CAUTION- Heater operates at High Temperatures. Keep
Electrical Cords, Drapes and Other Furnishings Away From
Heater. Maintain a minimum of 4 inches (102 mm) clear-
ance from all exposed heater surfaces (top and front) at all
times.
WARNING
!