beautypg.com

Dell PowerEdge RAID Controller S100 User Manual

Page 28

background image

28

Features

Virtual disk migration The controller supports automatic virtual disk migration

from a PERC S100 adapter to a PERC S300 adapter (or vice

versa). Manual intervention for migration is not required or

used by the PERC S100 adapter or

PERC S300 adapter.

CAUTION:

Before starting a virtual disk migration, power-

down both systems before removing or inserting the physical
disks. After the migration occurs, make sure that all of the
physical disks have been migrated and are present in the
virtual disk.

CAUTION:

The virtual disk is lost if you perform a virtual disk

migration during an OCE.

NOTE:

The PERC S100 adapter only supports SATA HDD and

SATA SSD disks. SAS disks cannot be migrated with a

PERC S100 adapter.

NOTE:

A bootable virtual disk cannot be migrated between

dissimilar controllers or dissimilar system models when the

system uses Microsoft Windows Server 2003 as its operating

system.

Virtual disk RAID

levels

Virtual disks at different RAID levels can be created.

Virtual disk

transformation

Virtual disk transformation can consist of:

• Capacity expansion, using OCE (to allocate additional

virtual disk space on the original physical disks or after

additional physical disks are added).

• Rebuilding (rebuilding data on a virtual disk consists of

using an available hot spare or backup physical disk).

Table 3-1. Features of the PERC S100 controller and PERC S300 controller

(continued)

RAID Controller Feature Description

A5_bk0.book Page 28 Thursday, February 10, 2011 8:34 PM