Dell PowerEdge RAID Controller S100 User Manual
Page 67

Troubleshooting
67
Table 7-5. Warning Messages: Dell Inc. PERC S100 or S300 Adapter BIOS
(continued)
Warning Message
Corrective Action
WARNING: Found
virtual disks
that are
Degraded and
Failed
This warning message appears when multiple virtual disks are
in Degraded and Failed state and Pause if Degraded or
Pause if Failed are set to ON at the PERC Virtual Disk
Management utility.
The following message appears after the warning is displayed:
--- Press
to enter setup ---
Press
boot, or press
Management utility to investigate the cause of the Degraded
and Failed virtual disks.
NOTE:
A boot virtual disk that is in a Failed state prevents the
operating system from booting.
To investigate the cause, check for the following:
• Whether the virtual disk is in Degraded status because one of
the physical disks of a RAID 1 or RAID 5 virtual disk has
failed, or one of the physical disks of a RAID 10 virtual disk
has failed.
Press
or missing. Remove and replace a failed physical disk. A
second physical disk failure could cause a Degraded virtual
disk to change to Failed status.
• Whether the virtual disk is in a Failed status because one or
more of the physical disks have failed.
Press
or missing. Remove and replace the failed physical disk or
disks.
A5_bk0.book Page 67 Thursday, February 10, 2011 8:34 PM