beautypg.com

Dell PowerEdge RAID Controller S100 User Manual

Page 66

background image

66

Troubleshooting

Table 7-4. Warning Messages: Dell Inc. PERC S100 or S300 Adapter BIOS

(continued)

Warning Message

Corrective Action

WARNING: Found
virtual disks
that are
Failed

This warning message appears when at least one virtual disk is

in a Failed state and Pause if Failed is set to ON at the

PERC Virtual Disk Management utility.
The following message appears after the warning is displayed:
--- Press to continue, or
to enter setup ---
Press to allow the operating system to continue its

boot, or press to enter into the PERC Virtual Disk

Management utility to investigate the cause of the Failed virtual

disk.

NOTE:

A boot virtual disk that is in a Failed state prevents the

operating system from booting.
To investigate the cause, check for the following:

• Determine if a single or multiple physical disks in a non-

redundant virtual disk have failed. If "yes," data is lost. Recover

the lost data from a backup storage source.

• Determine if two or more physical disks in a redundant virtual

disk have failed. If "yes," data is lost. Recover the lost data

from a backup storage source.

NOTE:

For a RAID 10, if a single physical disk fails in each

mirrored set, the redundant virtual disk goes to a Degraded status

but data is not lost. If two physical disks fail in one of the mirrored

sets, the redundant virtual disk goes to a Failed status and data is

lost.

A5_bk0.book Page 66 Thursday, February 10, 2011 8:34 PM