beautypg.com

Accessing the perc virtual disk management utility, 2 press

Page 48: Virtual disk management, Utility

background image

48

RAID Configuration and Management

Accessing the PERC Virtual Disk Management Utility

1 Boot the system and wait until the message Press to

Configure appears.

2 Press .

You have a maximum of three seconds to press , or the

system’s boot process continues.

CAUTION:

If SATA Controller is not set to RAID Mode, data might be destroyed.

Make sure to backup all data before changing modes.

NOTE:

If the PERC Virtual Disk Management utility does not appear and your

system uses a PERC S100, press F2 to access the Dell system BIOS. At the SATA
Settings
field, make sure that SATA Controller is set to RAID Mode. If

the settings are correct and the PERC Virtual Disk Management utility still does not

appear contact Dell support at support.dell.com.

Deleting Virtual Disks

Deletes one or more virtual disks that are configured for

the controller.

Swapping Two Virtual

Disks

Swaps virtual disks to enable them to load in any order.

Managing Global Hot

Spares

Enables you to create or delete a global hot spare(s).

Viewing Physical Disk

Details

Enables you to view detailed information about any

connected physical disk.

Viewing Virtual Disk

Details

Enables you to view detailed information about any

virtual disk.

Rescanning Disks

Rescans the disks to detect new or removed physical disks

or virtual disks.

Controller Options

Changes the selected controller options, such as booting

and virtual disk warnings.

Continuing to Boot

Enables the system to continue booting after you use the

PERC Virtual Disk Management utility.

Table 6-1. PERC Virtual Disk Management Utility Operations

(continued)

Operation

Description

A5_bk0.book Page 48 Thursday, February 10, 2011 8:34 PM